DISTRIBUTION AMPLIFIERS

PRECAUTIONS / SAFETY WARNINGS

1

Please read this manual carefully before using your DAA0106-V0A2Distribution Amplifier. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your DAA0106-V0A2and to prevent fire and shock hazard. Please read them carefully and heed all warnings.

1.1 GENERAL

Unauthorized personnel shall not open the unit since there are high-voltage components inside.

Qualified Altinex service personnel, or their authorized representatives must perform all service.

1.2SAFETY GUIDELINES FOR THE RACK- MOUNTING OF THE DAA0106-V0A2

Maximum operating ambient temperature is 35 (degrees C).

Never restrict the air flow through the devices’ fan or vents.

When installing equipment into a rack, distribute the units evenly. Otherwise, hazardous conditions may be created by an uneven weight distribution.

Connect the unit to a properly rated supply circuit.

Reliable Earthing (Grounding) of Rack-Mounted Equipment should be maintained.

1.3 INSTALLATION

For best results, place the DAA0106-V0A2Distribution Amplifier on a flat, leveled surface in a dry area away from dust and moisture.

To prevent fire or shock, do not expose this unit to rain or moisture. Do not place the DAA0106-V0A2Distribution Amplifier in direct sunlight, near heaters or heat radiating appliances, or near any liquid. Exposure to direct sunlight, smoke, or steam can harm internal components.

Handle the DAA0106-V0A2Distribution Amplifier carefully because dropping or jarring can damage internal components.

Do not place heavy objects on top of the DAA0106-V0A2. If the is to be mounted to a table or wall, use only Altinex made mounting accessories, such as rack mount shelf (DA1293FC, DA1294FC) and cables for optimum setup.

To turn off the main power, be sure to remove the cord from the power outlet. The power outlet socket should be installed as close to the equipment as possible, and should be easily accessible.

Do not pull the power cord or any cable that is attached to the DAA0106-V0A2Distribution Amplifier.

If the DAA0106-V0A2Distribution Amplifier is not used for an extended period, disconnect the power cord from the power outlet.

1.4 CLEANING

Unplug the DAA0106-V0A2power cord before cleaning. Clean surfaces with a dry cloth. Never use strong detergents or solvents, such as alcohol or thinner. Do not use a wet cloth or water to clean the unit.

1.5 FCC / CE NOTICE

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may

2

Page 3
Image 3
Altinex DAA0106-V0A2 manual Precautions / Safety Warnings, General, Installation, Cleaning, FCC / CE Notice

DAA0106-V0A2 specifications

The Altinex DAA0106-V0A2 is a high-quality audio and video distribution amplifier designed specifically for commercial AV applications. It plays a vital role in ensuring that signals are transmitted without degradation over long distances, thereby maintaining the integrity of both audio and video content. This model is engineered to support a variety of AV formats, providing versatility for different set-ups.

One of the standout features of the DAA0106-V0A2 is its ability to amplify a single input signal and distribute it to multiple outputs. This capability is essential in environments such as conference rooms, classrooms, and large venues where the same source needs to be viewed or heard in various locations. The amplifier offers six outputs, allowing users to connect multiple devices simultaneously while maintaining high quality.

In terms of technology, the DAA0106-V0A2 utilizes advanced electronic circuitry that minimizes noise and signal distortion, which is crucial for high-fidelity audio playback and clear video performance. It supports resolutions up to 4K, catering to modern display technologies and ensuring that even the most demanding visual content can be processed with ease.

Another notable characteristic of this distribution amplifier is its ease of installation and operation. The DAA0106-V0A2 has a user-friendly interface, making it an accessible solution for installers and end-users alike. With features such as LED indicators for power and signal status, troubleshooting becomes straightforward.

The amplifier is designed to be robust and reliable, with built-in protection mechanisms to prevent over-voltage and short-circuiting. Its compact form factor allows for flexible mounting options, and its durable construction ensures longevity even in environments where equipment may experience heavy use.

In summary, the Altinex DAA0106-V0A2 stands out as an essential tool for any AV installation requiring effective signal distribution. With its ability to handle multiple outputs, advanced signal processing technology, ease of installation, and reliable performance, it addresses the needs of modern audiovisual systems effectively. From educational institutions to corporate environments, this distribution amplifier enhances connectivity and enriches the AV experience.