9. […F] – Feedback
After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string or if the unit ID is zero.
10. […P] – Path
This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be loaded. See examples in ON and OFF commands.
11. [SW] – Switch
The switch command immediately connects inputs and outputs, which were previously set with the path command on this card or any other cards in the Enclosure.
Example:
[ON12VC6U3P]
[ON23SC7U3P]
[SW]
The system will return feedback as OK if the unit ID is zero.
12. [HELP]
This command displays all information available for user
13. [WR]
This command groups multiple cards in the Enclosure. Each unit contains a maximum of nine groups.
Command Format: [WRCn…GkUi]
Cn = card ID No. (n = slot # from 1 to 19)
Gk = group number (k = # from
Ui = unit number (i = # from
Example:
To group card #1, 2, and 3 as group 5 of unit #1, send the [WRC1C2C3G5U1] command.
After executing this command, card 1, 2, and 3 will be grouped together as group 5 of unit 1
14. [CLR]
This command clears the members for a single group or for all nine groups.
Command Format: [CLRGkUi]
Gk = group number (k = # from
Ui = unit number (i = # from
Example:
1)To clear group #1, send the [CLRG1U1] command. This command clears the members for the specified group only.
2)To clear all groups of unit 1, send the [CLRG[U1] command.
15.[G]
This command is used to request group data. With the command, the user can identify which input or output of a particular group is on.
Command Format: [GkUi]
Gk = group number (k = # from
Ui = unit number (i = # from
Example:
If group 1 has DA Cards with output 1 and 2 on, while group 2 has SW Cards with input 2 on:
[G1]: will return feedback as [On12G1].
[G2]: will return feedback as [On2G2].
16. [RD]
This command displays the members in each group.
Command Format: [RDGkUi]
Gk = group number (k = # from
Ui = unit number (i = # from
member = C1 - C19 (card 1 to 19)
Example:
To read member data for group 1 of unit 1, send the [RD] command. The system will return feedback as C1C2C19 G5U1.
8