Desa VTD-18NV-JHB, VTD-30NV-JHB, VTD-30PV-JHB Safety Information, Product Identification

Models: VTD-30NV-JHB VTD-18PV-JHB VTD-18NV-JHB VTD-24NV-JHB VTD-24PV-JHB VTD-30PV-JHB

1 20
Download 20 pages 47.49 Kb
Page 4
Image 4
SAFETY INFORMATION

SAFETY INFORMATION

Continued

Keep the log set area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

Children and adults should be alerted to the hazard of high tem- perature and should stay away to avoid burns or clothing ignition.

1.Do not place propane/LP supply tank(s) in- side any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

3.Never install the log set

in a recreational vehicle

where curtains, furniture, clothing or other flammable objects are less than 42" from the front, top or sides of the log set.

in high traffic areas

in windy or drafty areas

4.Before installing in a solid fuel burning fire- place, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, repair flue before operating appliance.

5.Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime- sized or larger).

6.This log set is designed to be smokeless. If logs ever appear to smoke, turn off appliance and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and the burning of manufacturing residues. You may wish to add more ventilation by opening a window.

7.To reduce the creation of soot, follow the instruc- tions in Cleaning and Maintenance, page 12.

8.The installation and provisions for combustion and ventilation air must conform with the Na- tional Fuel Gas Codes, ANSI Z233.1/NFPA 54, Section 5.3, Air for combustion and Ventilation.

9.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity (propane/LP units only).

10.Do not run log set

where flammable liquids or vapors are used or stored

under dusty conditions

11.Do not burn solid fuel in the fireplace after installing the log set. Do not use this log set to cook food or burn paper or other objects.

12.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

13.Turn log set off and let cool before servicing, installing or repairing. Only a qualified service person should install, service or repair log set.

14.Provide adequate clearances around air openings.

Product

Identification

Product WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

 

 

 

Log Set

 

 

 

Assembly

Grate

 

 

 

 

 

 

Piezo

 

 

 

Ignitor

Ceramic

 

 

 

Burner

 

Control

 

Chassis

 

Knob

ON/OFF

 

Assembly

 

 

Switch

 

 

 

Figure 1 - Product Identification

www.desatech.com114370-02C

Page 4
Image 4
Desa VTD-18NV-JHB, VTD-30NV-JHB, VTD-30PV-JHB, VTD-24PV-JHB, VTD-24NV-JHB Safety Information, Product Identification