 WARNING: If you smell gas

Troubleshooting

Continued

Manual background WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating log set where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

Appliance produces unwanted

1. Appliance burning vapors

1.

Open flue to maximum. Stop

odors

 

from paint, hair spray, glues,

 

using odor causing products

 

 

cleaners, chemicals, new car-

 

while appliance is running

 

 

pet, etc. (See IMPORTANT

 

 

 

 

2.

statement above)

2.

Refill supply tank (propane/LP

 

Low fuel supply (propane/LP

 

3.

only)

3.

only)

 

Gas leak. See Warning

Locate and correct all leaks

 

 

statement at top of

 

(see Checking Gas Connec-

 

 

page

 

tions, page 9)

 

Appliance shuts off in use (ODS

1. Not enough fresh air is avail-

1.

Open window and/or door for

operates)

2.

able

2.

ventilation

 

Low line pressure

Contact local natural or pro-

 

3.

ODS/pilot is partially

3.

pane/LP gas company

 

Clean ODS/pilot (see Cleaning

 

 

clogged

 

and Maintenance, page 13)

 

 

 

 

Gas odor even when control knob

1. Gas leak. See Warning

1.

Locate and correct all leaks

 

is in OFF position

 

statement at top of

 

(see Checking Gas Connec-

 

2.

page

2.

tions, page 9)

 

Control valve or gas control

Replace control valve or gas

 

 

defective

 

control

 

 

 

 

 

Gas odor during combustion

1. Foreign matter between

1.

Take apart gas tubing and

 

2.

control valve and burner

2.

remove foreign matter

 

Gas leak. See Warning

Locate and correct all leaks

 

 

statement at top of

 

(see Checking Gas Connec-

 

 

page

 

tions, page 9)