Inspecting Burners

BURNER FLAME PATTERN

Check flame pattern often. Figure 12 shows correct burner flame pattern.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles are burned by appliance, causing brief patches of orange flame.

If burner flame pattern is incorrect, as shown in Figure 13

turn appliance off (see To Turn Off Gas to Appliance

see Troubleshooting, page 13

Figure 12 - Correct Burner Flame Pattern

Yellow

Tipping

Figure 13 - Incorrect Burner Flame

Pattern

Cleaning and

Maintenance

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner and cir- culating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace and chimney inspected yearly by a qualified service person. Fireplace may needmore frequent cleaningdue to excessive lint from carpeting, bedding material, pet hair, etc.

Specifications

VTD-18NV-JHB

• Rating (Variable): 59,000 Btu/Hr

• Type Gas: Natural

• Ignition: Piezo

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water): Max - 10.5" W.C., Min* - 5.0" W.C.

VTD-24NV-JHB

• Rating (Variable): 69,000 Btu/Hr

• Type Gas: Natural

• Ignition: Piezo

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water): Max - 10.5" W.C., Min* - 5.0" W.C.

VTD-30NV-JHB

• Rating (Variable): 74,000 Btu/Hr

• Type Gas: Natural

• Ignition: Piezo

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water): Max - 10.5" W.C., Min* - 5.0" W.C.

VTD-18PV-JHB

• Rating (Variable): 59,000 Btu/Hr

• Type Gas: Propane/LP

• Ignition: Piezo

• Manifold Pressure: 10" W.C.

• Inlet Gas Pressure (in. of water): Max - 14" W.C., Min* - 11" W.C.

VTD-24PV-JHB

• Rating (Variable): 69,000 Btu/Hr

• Type Gas: Propane/LP

• Ignition: Piezo

• Manifold Pressure: 10" W.C.

• Inlet Gas Pressure (in. of water): Max - 14" W.C., Min* - 11" W.C.

VTD-30PV-JHB

• Rating (Variable): 74,000 Btu/Hr

• Type Gas: Propane/LP

• Ignition: Piezo

• Manifold Pressure: 10" W.C.

• Inlet Gas Pressure (in. of water): Max - 14" W.C., Min* - 11" W.C.

*For purpose of input adjustment

12

www.desatech.com

114370-02C