Altinex MT104-102 manual Troubleshooting Guide, Multi-Tasker

Models: MT104-102

1 12
Download 12 pages 20.33 Kb
Page 11
Image 11
TROUBLESHOOTING GUIDE

MULTI-TASKER

7.3.SUMMARY OF COMMANDS

1)[VER]: Receives software version

2)

[C]:

Receives status of the card

3)

[ON]:

Turns on one input for a single

 

 

card or a group of cards

4)[OFF]: Turns off one input for a single card or a group of cards

5) [SW]:

Switch (activates the preset

 

path)

6)[WR]: Groups multiple cards

7)[CLR]: Clears a single group or multiple groups

8)

[G]:

Requests group data

9)

[RD]:

Displays the members in each

 

 

group

10)[SIG]: Checks if signal presents.

11)[HELP]: Display commands.

TROUBLESHOOTING GUIDE

8

We have carefully tested and have found no problems in the supplied MT104-102; however, we would like to offer suggestions for the following:

8.1 LED IS NOT LIT

Cause 1: Card cage is not plugged in.

Solution: Plug card cage in. If the LED lights, the problem is solved. If the LED is still not lit, see Cause 2.

Cause 2: Card is not plugged in all the way.

Solution: Push the card in all the way. If the LED is still not lit, see Cause 3.

Cause 3: Card cage slot has a problem.

Solution 1: Test the card in other slots of the card cage. If the slot was damaged, the card may work in other slots. If other slots work and the LED lights, the problem is the card cage slot. The card cage may require service. Call ALTINEX at (714) 990-2300. If the other slots do not work and the LED is still not lit, see Solution 2.

Solution 2: Take any other known good card with an LED and verify that the slot used is good by seeing if the other card’s LED lights in that slot. If it lights, then the original card may be the source of the problem. Call ALTINEX at (714) 990-2300.

8.2 LED IS BLINKING RED

If the LED on the card is blinking red, find the error code. For example, if you are using card 5 of unit 1, send the [C5U1] command to see the status and error code. Note that card 5 refers to slot 5.

Cause 1: The CPU on the card is not working properly. If the CPU is not working, you will receive an ER01 message. The system will return feedback as [On1 ER01 C05] when using card 5 of unit 1.ER01 Code: CPU error

10

Page 11
Image 11
Altinex MT104-102 manual Troubleshooting Guide, Multi-Tasker