Example:
If one
To send command [VERC2U3], the Multi- Tasker™ Enclosure will return feedback as:
2. [C]
This command receives the status of the card.
Command Format: [CnUi]
Cn = card id (n = 1 to 19)
Ui = unit id (i = from 0 to 9) (refer to the MT100- 100 user’s guide for explanation)
Example:
If one
To send command [C2U3], the
If there is no card in slot #2 of unit 3, sending the [C2U3] command will not return any feedback.
ERROR CODES
ER01: CPU Error
This error indicates that the CPU is not working properly.
ER02: I²C Communication Error
This means that the communication between the
ER03: RS485 Communication Error
This type of error is a communication error between the
[CiS]
This command saves card status, such as Input number connected to the output, as a default configuration of the card.
3. [ON]
This command enables one input of a single card or a group of cards.
∙[ONmCnUiS]: for a single card
This command enables input “m” and disables all other inputs.
Default when plugged in = Input 1 is ON m = Input number (m = 1 to 6)
Cn = Card ID No. (n = slot # from 1 to 19)
S = saves command to memory
Example:
If all of the inputs on the
1)[ON1C5U3]: Turns ON only input 1 of the
2)[ON3C5U3]: Turns ON only input 3 (input 1 is now OFF).
∙[ONmGkUiS]: for a group of cards
This command enables input "m" for each card in group "k" of unit "i".
m = card input (m = # from
Gk = group number (k = # from
S = saves command to memory
Example:
[ON1G1U1]: Turns ON input 1 for each card in group 1 of unit 1.
∙[ON…P]: sets path
This command will set the path for the output, but it is not active until the switch command is executed ([SW]). Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be loaded.
Command Format: [ONmCnUiP] m = input number (m = 1 to 6)
Cn = card ID no. (n = slot # from 1 to 19)
P = path
7