MULTI-TASKER

S =

saves command to memory

Example:

[ON1VG1U1]: Turns ON C-Video input 1 for each card in group 1 of unit 1.

[ON…..P]: sets path

This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The Path for outputs may be set on a single card or for multiple cards. In either case, all Paths will be switched when the [SW] command is executed.

Command Formats: [ONmVCnUiP] and [OnmSCnUiP]

m = Input number (m = 1 to 4) (input 4 is internal)

S= activates S-Video input V = activates C-Video input

Cn = card ID (n = slot # from 1 to max slots) P = path

card or a group of cards.

SINGLE CARD

[OFFmVCnUiS] for Composite Video

[OFFmSCnUiS] for S-Video

This command disables input “m” or all inputs. [OFFVC5CnUi]: Turns OFF all C-Video inputs of the MT104-107card.

m

=

Input number (m = 1 to 4)

 

 

(input 4 is internal)

Cn

=

Card ID (n = slot # from 1 to max slots)

Ui

=

Unit ID number (i = 0 to 9)

S= activates S-Video input V = activates C-Video input

S = saves command to memory

Example:

Card 5 of unit 3 has S-Video input 1 and C-Video input 2 ON. The following commands can be used to turn OFF the inputs.

1)[OFF1SC5U3] or [OFFSC5U3]: Turns OFF S-Video input.

2)[OFFVC5U3]: Turns OFF C-Video input.

Example:

There are two MT104-107of unit 3. Enable S-Video S-Video input 3 of card 7 the following commands:

[ON1SC6U3P] [ON3SC7U3P] [SW]

cards in slot 6 and 7 input 1 of card 6 and simultaneously. Use

GROUP OF CARDS

[OFFmVGkUiS] for Composite Video

[OFFmSGkUiS] for S-Video

This command disables input "m" for each card in group "k" of unit "i".

m= Input number (m = 1 to 4) (input 4 is internal)

Cn

=

Card ID (n = slot # from 1 to max slots)

Ui

=

Unit ID number (i = 0 to 9)

If "F" is included, use the [ONmCnUiPF] command or the [ONmCnUiFP] command.

[ON…..F]: feedback

After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string.

Example:

[ON1VC2U3F]: if path is not set

[ON1VC2U3PF]: if path is set

5. [OFF]

This command disables one input of a single

S= activates S-Video input V = activates C-Video input

S = saves command to memory

Example:

1)[OFF1SG1U1]: Turns OFF S-Video input 1 for each card in group 1 of unit 1.

2)[OFF1VG1U1]: Turns OFF C-Video input 1 for each card in group 1 of unit 1.

9