MULTI-TASKER

STATUS

MIN

MAX

Default

Command

Value

Value

Value

[ HPOS ]

0

20

5

 

 

 

 

[ VPOS ]

0

20

19

 

 

 

 

[ HSIZE ]

0

20

19

 

 

 

 

[ VSIZE ]

0

20

19

 

 

 

 

[ BRIG ]

0

20

10

 

 

 

 

[ SHARP ]

0

3

2

 

 

 

 

[ COLOR ]

0

10

10

 

 

 

 

[ HUE ]

0

10

10

 

 

 

 

Attempting to cycle past the minimum or maximum values will have no effect on the attribute's value.

Any command other than [ + ] or [ - ] will reset the previous selection and the STATUS command will need to be reissued.

Example:

There is an MT106-101 in slot 4 of unit ID 2. The current Horizontal Position is set to a value of 10. Use the [ + ] and [ - ] controls to find the best horizontal position. Starting from 10, first increment the value to 12. Next, decrement the value back down to 8 for the best picture.

[HPOSC4U2] 10 [ + ][ + ][ - ][ - ][ - ][ - ]

[HPOSC4U2]

= STATUS/Current value

10

= Feedback of current value

[ + ][ + ]

= Increment twice to 12

[ - ][ - ][ - ][ - ]

= Decrement 4 times to 8

[HPOSC4U2]

= STATUS/Current Value

8

= Feedback of new value

7.[HPOSnCi] - Set Value

This command sets the Horizontal Position to an absolute value. It also makes the Horizontal Position adjustment the active control.

Command Format: [HPOSnCiUy]

n = a value from 0 to 20 (Default = 5)

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-101 in slot 7 of unit ID 4. Set the Horizontal Position to the maximum value of 20 by sending the command [HPOS20C7U4].

8.[HPOSCi] - Status/Adjust

This command selects the Horizontal Position adjustment and makes it the active control. It is also used to return the status of the current Horizontal Position. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [HPOSCiUy]

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-101 in slot 4 of unit ID 1. View the current Horizontal Position and adjust for the best image.

[HPOSC4U1] 10

[HPOSC4U1]

= STATUS command

10

= Feedback of current value

[ + ] & [ - ]

= Adjust as required

9.[VPOSnCi] - Set Value

This command sets the Vertical Position to an absolute value and makes the Vertical Position adjustment the active control.

Command Format: [VPOSnCiUy]

n = a value from 0 to 20 (Default = 19)

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-101 in slot 2 of unit ID 3. Set the Vertical Position to the value of 12 by sending the command [VPOS12C2U3].

10. [VPOSCi] - Status/Adjust

9

Page 10
Image 10
Altinex MT106-101 manual Status MIN MAX