MULTI-TASKER

This command selects the Vertical Position adjustment and makes it the active control. It also returns the status of the current Vertical Position. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [VPOSCiUy]

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-101 in slot 2 of unit ID 3. View the current Vertical Position and adjust the image for the best vertical position.

[VPOSC2U3] 10

[VPOSC2U3]

= STATUS/Current value

10

= Feedback of current value

[ + ] & [ - ]

= Adjust as required

11. [HSIZEnCi] - Set Value

This command sets the Horizontal Size to an absolute value and makes the Horizontal Size adjustment the active control.

Command Format: [HSIZEnCiUy]

n = a value from 0 to 20 (Default = 19)

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-101 in slot 2 of unit ID 3. Set the Horizontal Size to the value of 12 by sending the command [HSIZE12C2U3].

12. [HSIZECi] - Status/Adjust

This command selects the Horizontal Size adjustment and makes it the active control. It also returns the status of the current Horizontal Size. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [HSIZECiUy]

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-101 in slot 2 of unit ID 3. View the current Horizontal Size and adjust the image to the center of the screen.

[HSIZEC2U3] 10

[HSIZEC2U3]

= STATUS/Current value

10

= Feedback of current value

[ + ] & [ - ]

= Adjust as required

13. [VSIZEnCi] - Set Value

This command sets the Vertical Size to an absolute value and makes the Vertical Size adjustment the active control.

Command Format: [VSIZEnCiUy]

n = a value from 0 to 20 (Default = 19)

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-101 in slot 1 of unit ID 1. Set the Vertical Size to the value of 6 by sending the command [VSIZE6C1U1].

14. [VSIZECi] - Status/Adjust

This command selects the Vertical Size adjustment and makes it the active control. It also returns the status of the current Vertical Size. As the active control, it may be adjusted using the [ + ] and [ - ] commands.

Command Format: [VSIZECiUy]

Ci = card ID (i = slot number)

Uy = unit id (i = 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

There is an MT106-101 in slot 2 of unit ID 3. View the current Vertical Size and adjust the vertical size for the best fit.

[VSIZEC2U3] 10

[VSIZEC2U3]

= STATUS/Current value

10

= Feedback of current value

[ + ] & [ - ]

= Adjust as required

10

Page 11
Image 11
Altinex MT106-101 manual VPOSC2U3, HSIZEnCi Set Value, HSIZECi Status/Adjust, HSIZEC2U3, VSIZEnCi Set Value, VSIZEC2U3