Altinex MT108-102 manual Multi-Tasker

Models: MT108-102

1 13
Download 13 pages 24.24 Kb
Page 10
Image 10
Manual background

MULTI-TASKER

Example:

If 2 cards are in slots 6 and 7 of unit 3:

To disable outputs 1 and 2 of card 6 and outputs 3 and 4 of card 7 simultaneously, use the following commands:

[OFF12C6U3P] [OFF34C7U3P] [SW]

If "F" is included use the [OFFmCnUiPF] command or the [OFFmCnUiFP] command.

[OFF…..F]: feedback

After processing a command, an OK ER will be returned as feedback if "F" is included at the end of a command string.

Example:

[OFF1C2U3F]: if path is not set

[OFF1C2U3PF]: if path is set

7.[…S] – Save

This command will save the configuration

command being sent in memory. When sending the command [ON1C4S], after reset or power up, output 1 on C4 will be enabled.

8.[…F] – Feedback

After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string.

9.[…P] – Path

This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be loaded. See examples in ON and OFF commands.

10.[SW] – Switch

The switch command immediately connects inputs and outputs, which were previously set with the PATH command on this card and all other cards in the MT100-100.

11. [HELP]

This command displays all information available for user Multi-Tasker interface commands.

Command Format: [HELPCnUi]

Cn = card ID number (n = # from 1 to 19)

Ui = Unit ID (i = # from 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

In order to view the RS-232 commands available for the MT108-103card in slot 2 of unit 3, send the command [HELPC2U3]. The commands along with a brief description will be displayed in the Terminal Window.

12. [WR]

This command groups multiple cards in the MT100-100 Enclosure. Each unit contains a maximum of nine groups.

Command Format: [WRCn…GkUi]

n= card ID No. (n = slot # from 1 to 19) k = group number (k = # from 1-9)

i = unit number (i = # from 0-9)

Example:

To group cards #1, 2, and 3 as group 5 of unit #1, send the command [WRC1C2C3G5U1]. After executing this command, cards 1, 2, and 3 of unit 1 will be grouped together as group 5.

13. [CLR]

This command clears the members for a single group or for all nine groups.

Command Format: [CLRGkUi]

k

=

group number (k = # from 1-9)

i

=

unit number (i = # from 0-9)

Example:

a)To clear group #1, send the [CLRG1U1] command. This command clears the members for the specified group only.

b)To clear all groups of unit 1, send the [CLRG[U1] command.