Example:
1.[ON1G5U1]: Turns ON output 1 for each card in group 5 of unit 1.
2.[ONG5U1]: Turns ON all outputs for each card in group 5 of unit 1.
[ON…P]: sets path
This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded.
Command Format: [ONmCnUiP]
m= number (m =1 to 4)
n= card ID No. (n = a slot # from 1 to 19)
i= unit ID
P = path
Example:
If 2 cards are in slot 6 and 7 of unit 3: To enable outputs 1 and 2 of card 6 and outputs 3 and 4 of card 7 simultaneously, use the following commands:
[ON12C6U3P] [ON34C7U3P] [SW]
If "F" is included use the [ONmCnUiPF] command or the [ONmCnUiFP] command.
[ON…..F]: feedback
After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string.
Example:
[ON1C2U3F]: if path is not set
[ON1C2U3PF]: if path is set
6.[OFF]
This command disables one or more outputs of a single card or a group of cards.
[OFFmCnUi]: for a single card
This command disables output “m” without affecting any other outputs.
m= output number (m = 1 to 4)
n= card ID No. (n = slot # from 1 to 19)
i= Unit ID number (i = 0 to 9)
[OFFCnUi]: Turns OFF all outputs of the card
Example:
1)If card 5 of unit 3 has output 1, 2 and 3 ON:
a)[OFF1C5U3]: Turns OFF output 1 while outputs 2 and 3 remain ON.
b)[OFF23C5]: Turns OFF outputs 2 and 3.
2)If card 5 of unit 3 has outputs 1, 2, 3 and 4 ON:
a)[OFFC5U3]: Turns OFF all outputs, which is equivalent to [OFF1234C5U3].
[OFFmGkUi]: for a group of cards
This command disables output "m" for each card in group "k" of unit "i".
Command Format: [OFFmCnUiP]
m= card output (m = # from
Example:
1.[OFF1G5U1]: Turns OFF output 1 for each card in group 5 of unit 1.
2.[OFFG5U1]: Turns OFF all outputs for each card in group 5 of unit 1.
[OFF…..P]: sets path
This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded.
Command Format: [OFFmCnUiP]
m= number (m =1 to 4)
n= card ID No. (n = a slot # from 1 to 19) P = path
8