Altinex MT108-105 manual Sel, Vol, CLR - Card, CLRCnUi, 8. …S - Save, CLR - Group, CLRGkUi, 10. WR

Models: MT108-105 MT108-104

1 11
Download 11 pages 28.84 Kb
Page 9
Image 9
5.[SEL]

MULTI-TASKER

Example:

If cards 1, 2, and 3 are grouped as group 5 of unit 1, send the command [SEL1G5U1]. Then send the commands [ + ], and [ - ] to increase or decrease the volume for cards 1, 2, and 3 simultaneously.

5.[SEL]

This command selects the individual input for adjusting the volume level of each output.

Command Format: [SELmCnUi]

SELm = volume select for output m. (m = 1-4)

Cn = card ID (n = from 1 to 19)

(1-8 for MT100-101 or 1-4 for MT100-106) Ui = unit ID (i = from 0 to 9)

After the [SEL] command is executed, the [ + ] and [ - ] commands must be executed immediately in order to increase or decrease the volume. Any other command (or an empty command such as [ ] ) will terminate the [SEL] command.

6.[VOL]

This command allows the Multi-Tasker to send an absolute volume level to the MT108-105.

Command Format: [VOLmAnCi] VOLm = output select (m = 1 to 4) An = amplitude level (n = 0 to 16) Ci = card ID (i = from 1 to 19)

(1-8 for MT100-101 or 1-4 for MT100-106) Ui = unit ID (i = from 0 to 9)

Example:

If there is an MT108-105 card in Slot 4 of Unit 0, sending the command [VOL1A16C4] will set the volume of output 1 to the maximum level of 16.

7.[CLR] - Card

The command clears all volumes to maximum for a single card. With this command, 200ms is

needed for execution. Insert a 200ms delay [WAIT] time after sending this command.

[CLRCnUi]

Cn = card ID No. (n = slot # from 1 to 19) (1-8 for MT100-101 or 1-4 for MT100-106)

Ui = Unit ID number (i = 0 to 9)

After [CLR] is executed, send [Cn] and receive feedback as:

Vol1=16/16

Vol2=16/16

Vol3=16/16

Vol4=16/16

8.[…S] – Save

This command will save the volume configuration command being sent in memory. When sending the command [VOL1A10C4S], after reset or power up, the volume level of output 1 on C4 will be level 10.

9.[CLR] - Group

This command clears the members for all nine groups.

[CLRGkUi]

Gk = group number (k = # from 1-9) Ui = unit number (i = # from 0-9)

Example:

a)To clear group #1, send the command [CLRG1U1]. This command clears the members for the specified group only.

b)To clear all groups of unit 1, send the command [CLR G[U1].

10.[WR]

This command groups multiple cards in the MT100-100 Enclosure. Each unit contains a maximum of nine groups.

Command Format: [WRCn… GkUi]

Cn = card ID No. (n = slot # from 1 to 19) (1-8 for MT100-101 or 1-4 for MT100-106)

Gk = group number (k = # from 1-9)

8

Page 9
Image 9
Altinex MT108-105 manual Sel, Vol, CLR - Card, CLRCnUi, 8. …S - Save, CLR - Group, CLRGkUi, 10. WR, Multi-Tasker, Example