7.5 MASTER/SLAVE CONTROL (RS-232):

SWITCHERS

7.5 MASTER/SLAVE CONTROL (RS-232):

The feedback codes allow multiple MX2226AT Switchers to be connected in a Master-Slave configuration, if desired.

When the control port of two units are connected as shown below, the slave unit duplicates the actions of the master unit. The slave unit can still be controlled from its front panel or through another RS-232 control; however this configuration is used when multiple MX2226AT units must be controlled through a single RS-232 source.

Master MX2226AT

Slave MX2226AT

Terminal block pin

Terminal block pin

TX

RX

GND

GND

Master-Slave Control Port Connection of the

MX2226AT

7.6 LOOP CONTROL

In some applications, it may be necessary to switch a number of computer video sources to a single presentation display, requiring more inputs than are available from an individual switcher.

To create a larger switcher with more input, the output of the previous unit can be looped to another unit. To maintain the completeness and availability of the incoming video signal, no more than 3 units should be looped. Keep in mind that the Looping Configuration will eliminate one usable input for each looped unit. For example, if two 6-in 1-out switchers were looped together, there would be 11 usable inputs.

The loop control feature forces all looped units to select input 6 so that the incoming signal will automatically pass through. If input from switcher no. 1 is selected then input no. 6 is automatically selected on switcher no. 2, so that an incoming signal from the output of switcher no. 1 is passed to the output of switcher no. 2.

9

11-IN 1-OUT SWITCHER

MX2226AT Unit #1

MX2226AT Unit #2

The coaxial cable between looped switchers must be arranged so that Input 6 always accepts the loop output.

FREQUENTLY ASKED QUESTIONS

8

 

 

 

 

No

Question

Answer

 

 

 

 

 

1

When I press

You must press and hold

 

 

the RESET

the button for approximately

 

button, the

2 seconds, until you hear a

 

 

switcher does

short beeping sound until all

 

not respond.

of the LED lights flash. This

 

Why?

is designed to avoid

 

 

 

accidental resetting of the

 

 

 

unit just by touching the

 

 

 

key.

 

2

When l press

You must press and hold

 

 

the SOUND

the button for approximately

 

button, the

2 seconds, until you hear

 

 

switcher

the beeping sound. This is

 

 

doesn’t

done to set the switcher in

 

 

respond.

either BEEP ON or BEEP

 

9