I N S T A L L A T I O N
ELECTRICAL CONNECTION
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
DANGER
ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED SERVICE TECHNICIAN IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES.
1.An identification tag is permanently mounted on the cabinet.
2.Plug cabinet into a properly grounded receptacle ONLY, positioning the unit so the power supply cord is easily accessible in case of an emergency.
3.If necessary, a proper receptacle or outlet configuration as required for this unit, must be installed by a licensed electrician in accordance with applicable, local electrical codes.
NOTE: CE approved appliances must be connected to an electrical circuit that is protected by an external GFCI outlet.
For CE approved units: To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an
Hard wired models:
Hard wired models must be equipped with a country certified external allpole disconnection switch with sufficient contact separation.
If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.
D A N G E R
To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/ NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1 or local codes.
ELECTRICAL •
voltage | phase | cycle/hz | amps | kW | cord & plug included |
120 (agcy) | 1 | 60 | 12.5 | 1.5 | nema |
|
|
|
|
| 15A- 125V plug |
60 | 7.0 | 1.6 | nema | ||
at 208 | 1 | 60 | 5.9 | 1.2 | 15A - 250V plug |
at 240 | 1 | 60 | 6.8 | 1.6 |
|
230 (agcy) | 1 | 50/60 | 6.5 | 1.5 | cee 7/7 |
|
|
|
|
| |
ELECTRICAL • |
| ||||
voltage | phase | cycle/hz | amps | kW | cord & plug included |
120 (agcy) | 1 | 60 | 17.5 | 2.1 | nema |
|
|
|
|
| 20A- 125V plug |
60 | 8.8 | 2.1 | nema | ||
208 | 1 | 60 | 7.7 | 1.6 | 15A - 250V plug |
240 | 1 | 60 | 8.9 | 2.1 |
|
230 (agcy) | 1 | 50/60 | 8.4 | 2.0 | cee 7/7 |
|
|
|
|
| |
ELECTRICAL • |
| ||||
voltage | phase | cycle/hz amps | kW | cord & plug included | |
120 (agcy) 1 | 60 | 24.0 | 2.9 | nema | |
power switch in low position | 16.0 | 1.9 | 20A- 125V plug | ||
|
|
|
|
| nema |
power switch in high position | 25.0 max | 3.0 | 30A - 125V plug | ||
60 | 13.5 | 3.3 | nema | ||
at 208 | 1 | 60 | 11.8 | 2.5 | 15A - 250V plug |
at 240 | 1 | 60 | 13.6 | 3.3 |
|
230 (agcy) | 1 | 50/60 13.0 | 3.0 | cee 7/7 | |
|
|
|
|
|
Wire diagrams are located inside the top of the unit..