Alto-Shaam 1000-BQ2/128 manual Danger, Electrical Connection, Hard wired models, D A N G E R

Models: 1000-BQ2/128 1000-BQ2/96 1000-BQ2/192

1 29
Download 29 pages 23.95 Kb
Page 8
Image 8
ELECTRICAL CONNECTION

I N S T A L L A T I O N

ELECTRICAL CONNECTION

 DANGER DANGER

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

ENSURE POWER SOURCE DANGER

ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED SERVICE TECHNICIAN IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES.

1.An identification tag is permanently mounted on the cabinet.

2.Plug cabinet into a properly grounded receptacle ONLY, positioning the unit so the power supply cord is easily accessible in case of an emergency.

3.If necessary, a proper receptacle or outlet configuration as required for this unit, must be installed by a licensed electrician in accordance with applicable, local electrical codes.

NOTE: CE approved appliances must be connected to an electrical circuit that is protected by an external GFCI outlet.

For CE approved units: To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an equalization-bonding stud is provided. An equalization bonding lead must be connected to this stud and the other appliances / metal parts to provide sufficient protection against potential difference. The terminal is marked Hard wired models: with the following symbol.Manual background

Hard wired models:

Hard wired models must be equipped with a country certified external allpole disconnection switch with sufficient contact separation.

If a power cord is used for the connection of the

product an oil resistant cord like H05RN or H07RN

or equivalent must be used.

D A N G E R

To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/ NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1 or local codes.

ELECTRICAL • 1000-BQ2/96

voltage

phase

cycle/hz

amps

kW

cord & plug included

120 (agcy)

1

60

12.5

1.5

nema 5-15p

 

 

 

 

 

15A- 125V plug

208-240 (agcy) 1

60

7.0

1.6

nema 6-15p

at 208

1

60

5.9

1.2

15A - 250V plug

at 240

1

60

6.8

1.6

 

230 (agcy)

1

50/60

6.5

1.5

cee 7/7

 

 

 

 

 

220-230V plug

ELECTRICAL • 1000-BQ2/128

 

voltage

phase

cycle/hz

amps

kW

cord & plug included

120 (agcy)

1

60

17.5

2.1

nema 5-20p

 

 

 

 

 

20A- 125V plug

208-240 (agcy) 1

60

8.8

2.1

nema 6-15p

208

1

60

7.7

1.6

15A - 250V plug

240

1

60

8.9

2.1

 

230 (agcy)

1

50/60

8.4

2.0

cee 7/7

 

 

 

 

 

220-230V plug

ELECTRICAL • 1000-BQ2/192

 

voltage

phase

cycle/hz amps

kW

cord & plug included

120 (agcy) 1

60

24.0

2.9

nema 5-20p

power switch in low position

16.0

1.9

20A- 125V plug

 

 

 

 

 

nema 5-30p

power switch in high position

25.0 max

3.0

30A - 125V plug

208-240 (agcy) 1

60

13.5

3.3

nema 6-15p

at 208

1

60

11.8

2.5

15A - 250V plug

at 240

1

60

13.6

3.3

 

230 (agcy)

1

50/60 13.0

3.0

cee 7/7

 

 

 

 

 

220-230V plug

Wire diagrams are located inside the top of the unit..

1000-BQ2series operation & care manual • 6

Page 8
Image 8
Alto-Shaam 1000-BQ2/128 manual Danger, Electrical Connection, Hard wired models, D A N G E R, I N S T A L L A T I O N