simple contro l smokersinsta llatio n/opera tion/service manual - pg. 10
ELECTRICAL CONNECTION
INSTALLATION
DANGER

ELECTRICAL CONNECTIONS MUST

BE MADE BY A QUALIFIED SERVICE

TECHNICIAN IN ACCORDANCE WITH

APPLICABLE ELECTRICAL CODES.

DANGER

To avoid electrical shock, this

appliance MUST be adequately

grounded in accordance with local

electrical codes or, in the absence of

local codes, with the current edition

of the National Electrical Code ANSI/

NFPA No. 70. In Canada, all electrical

connections are to be made in

accordance with CSA C22.1, Canadian

Electrical Code Part 1 or local codes.

DANGER

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

Wire diagrams are located inside the bonnet of the unit.
The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National Electrical
Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is easily
accessible in case of an emergency. Arcing will occur
when connecting or disconnecting the unit unless all
controls are in the “off” position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed by
a licensed electrician in accordance with applicable
local electrical codes.
Supply cords used with this equipment shall be
oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other equivalent
synthetic elastomer-sheathed cord (Code designation
60245 IEC).
REGARDING INTERNATIONAL STANDARD UNITS:
If the unit is not equipped with flexible cord and
plug, an all-pole country approved disconnection
device which has a contact separation of at least 3mm
in all poles must be incorporated in the fixed wiring
for disconnection. When using a cord without a plug,
the green/yellow conductor shall be connected to the
terminal which is marked with the ground symbol.
If a plug is used, the socket outlet must be easily
accessible. If the power cord needs replacement, use
a similar one obtained from the distributor.
For 230V units: To prevent an electrical shock hazard
between the appliance and other appliances or metal
parts in close vicinity, an equalization-bonding stud
is provided. An equalization bonding lead must be
connected to this stud and the other appliances /
metal parts to provide sufficient protection against
potential difference. The terminal is marked with the
following symbol.
NOTE: CE approved appliances must be
connected to an electrical circuit that is
protected by an external GFCI outlet.
Hard wired models:
Hard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.
ELECTRICAL - 767-SK
vOLTaGE PHaSE cycLE/H z aMPS kW cOrD & PLu G
120 1 60 16.0 1.9 NeMa 5-20p
20a - 125v plug
208-240 (agcy) 1 60 15.9 3.3 no cord
at 208 1 60 15.5 3.2 or plug
at 240 1 60 12.3 2.9
230 1 50/60 12.2 2.8 cee 7/7
220-230v plug
ELECTRICAL - 1767-SK
vOLTaGE PHaSE cycLE/H z aMPS kW cOrD & PLuG
208-240 (agcy) 1 60 30.8 6.4 no cord
at 208 1 60 31.0 6.5 or plu g
at 240 1 60 24.6 5.9
230 1 50/60 24.3 5.6 n o cord or plu g
ELECTRICAL - 1000-SK-I
vOLTaGE PHaSE cycLE/H z aMPS kW cOrD & PLuG
208-240 (agcy) 1 60 31.4 6.5 no cord
at 208 1 60 30.7 6.4 or plug
at 240 1 60 24.3 5.8
230 1 50/60 24.1 5.5 n o cord or plu g
ELECTRICAL - 1000-SK/II
vOLTaGE PHaSE cycLE/H z aMPS kW cOrD & PLu G
208-240 (agcy) 1 60 15.7 3.3 NeMa 5-20p
at 208 1 60 15.3 3.2 20a - 125v plug
at 240 1 60 12.1 2.9
230 1 50/60 12.2 2.8 cee 7/7
220-230v plug