ELE CTRICAL CON NECTION

The appliance must be inst alled by a qualified serv ice technician. The oven must be properly grounded in accordance with the Nat ional Elec trical Cod e and applic able loca l codes.

DAN GER

To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1 or local codes.

Plug the unit into a properly grounded recep tac le

ONLY, positioning

the unit so that the plug is

easi ly accessible in case of an emer gency. Arcing

will occur when connecting or discon necting the

unit unless all controls are in the “OFF” position .

Proper receptacle

or outlet configuration or

perm anent wiring

for this unit must be installe d

by a licensed electricia n in accordance with appl ica ble loca l electrica l codes .

IN STA LLA TION

After wiri ng and pow er con nection has been completed, turn the main power switch to the “ON” posi tion. The main power switch can be left “ON ” for daily use , but should be turned “OFF” whe n cleaning or performing mainte nance or repai rs to the rotisse rie.

REGARDING INTERNATIONAL STANDARD UNITS: If the unit is not equ ipped with flexible cord

with plug, an all-p ole cou ntry approved discon necti on dev ice which has a cont act separation of at least 3mm in all poles mus t be incorp ora ted in the fix ed wirin g for dis conne ctio n. When using a cord without a plug , the green/yellow con ductor shall be connec ted to the terminal which is marked with the ground symbo l. If a plug is use d, the sock et out let must be eas ily acce ssi ble. If the power cord needs replaceme nt, use a sim ilar one obtained from the distri butor. For 230V units: To prevent an electrical shock hazard between the appliance and other appliances or metal parts in clos e vici nity, an equa lization bonding stud is provide d. An

equa lization bonding lead must be conne cted to this stud and the oth er appliances / metal parts to provide suff ici ent protect ion against potential difference. The terminal is marked with the

follo wing symbol.

ELEC TRIC AL

 

AMPS

KW

 

 

 

VOLTAGE

PHAS E CYCLE /HZ

 

 

 

120

1

50/60

15.0

1.8

20A,

125V

PLUG

 

 

 

 

 

NE MA 5-20P

208-240V

AT 208

1

50/60

8.5

1.8

15A,

250V

PLUG

AT 240

1

50/60

9.5

2.3

NE MA 6-15P

15A,

250V

PLUG

230

3

50/60

9.0

2.1

NE MA 6-15P

220-2 30V

PLUG

 

 

 

 

 

CEE 7/7

Wire diagrams are located inside the access panel of the unit.

DA NGE R

ELECTRICAL CONNECTIONS MUST

BE MADE BY A QUALIFIED SERVICE

TECHNICIAN IN ACCORDANCEWITH

APPLICABLE ELECTRICAL CODES.

D AN GER

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

AR- 7H Hot Hol di ng Ro tis ser ie Companion Operat ion & Care Manual • 5