BreezeNET DS.11 Series User Manual

2-16

Name Description Functionality
ETH
Ethernet activity/
connectivity indication
OFF –Ethernet connectivity is OK.
No traffic activity detected on the port.
Blinking Green –Ethernet connectivity is OK, with traffic on
the port.
Red – No Ethernet connectivity. When this state occurs, check
the Ethernet cable and indoor-to-outdoor cable connections.
RSSI/Load
BAR
RB-DS.11: Received Signal Strength Indication
BU-DS.11: Number of associated RB-DS.11 units
Table 2-3: Outdoor Unit LEDs
What to do if the Self Test Fails
Upon failure of the self-test, the WLAN, DC Power and ETH LEDs, as well as the
leftmost 2 LEDs of the RSSI bar are blinking synchronously. The statuses of the
other 8 LEDs of the bar indicate the specific problem type.
If the Self-Test fails, try the following:
Reset unit (Disconnect/reconnect the power).
Check the indoor-to-outdoor cable.
Reset to factory defaults (see page 3-31).
If all fails, contact technical support and provide details regarding the status of the
RSSI LEDs.