The DS.11 Configuration Utility
3-9 Networking Parameters-CPE Table Tab (BU only)
Figure 3-5: Networking Parameters Tab (BU)
The CPE Table tab enables defining the VLAN functionality for data frames for each
of the RBs associated with the BU. The VLAN functionality of associated RBs that
are not defined in the CPE Table is defined by the VLAN ID Access and VLAN
Priority Access parameters in the General tab.
VLAN ID: Defines the VLAN functionality for the specific RB. A value from 1 to
4094 defines Access port functionality. A value of 65535 (no VLAN) defines
Hybrid port functionality.
Valid values: 1 to 4094 or 65535
VLAN Priority: Defines the VLAN Priority field when a VLAN tag is added to a
packet, according to the functionality described below
Valid values range from 0 to 7.
To add an RB to the table: Enter the MAC Address in the Add/Delete MAC
Address text box. Select the VLAN ID and VLAN Priority, check the Add check
box and click Apply.
To remove an RB from the table: Enter the MAC Address in the Add/Delete
MAC Address text box. Check the Delete check box and click Apply.