Upgrade Page
Voice Gateways System Manual 69
file is done automatically, including a restart of the unit. When the installation is
complete and the unit has restarted, the Home Product Info page will be displayed
(if not, click on the Refresh button).
The version R2H implementation of the dialplan module is fully compliant with
RFC3435. However, some previously acceptable dialplans are inconsistent with
RFC3435 operation and must therefore be changed to ensure continued operation
consistent with previous releases. You should review your dialplan to ensure that
the dial behavior will continue to be that required by your customers.
For example, the default dialplan should be changed from (x.#|x.T) to (xx.#|xx.T).
It is recommended to review your dialplan to ensure that its proper operation.
You can change the dialplan as follows:
Default dialplan
If an INI file is not used: upgrade to version R2H and then install the INI file
provided with the upgrade package.
If an INI file is used: you will be provided with an updated INI file.
Non-default dialplan
If an INI file is not used: Refer to Section 3.7.7 for information on updating
your dialplan. The dialplan can be changed via the Telephone menu, or via
option 43.
If an INI file is used: you will be provided with an updated INI file.
3.10.1 Downloader Result Codes (hexadecimal)
If something goes wrong during download or installation, you will be notified
according to the following:
0 (0x00): normal boot (no upgrade requested or needed)
bit-0 (0x01): upgrade requested or main application not valid
bit-1 (0x02): failed to download new image
bit-2 (0x04): TFTP server not defined
bit-3 (0x08): TFTP file not defined