Troubleshooting Procedures

Indicator Lights and Diode Assembly

NOTE: Test diode, disconnect wires and connect meter

Some Models

on 10 KΩ scale. Meter should indicate continuity

with leads connected one direction and no

Power Connected

continuity with leads in the reverse direction for a

1.

Set meter to measure at least 250 VAC. Connect one

diode to be operating properly. If no continuity,

 

meter lead to P of control and the other to L2.

diode is open. If continuity in both directions,

2.

Connect cooktop to power source. Turn on control.

diode is shorted. In either case, replace diode.

3.Meter should indicate 240 VAC. If it does not, replace control.

4.If meter indicates 240 VAC and indicator does not light, move lead from P of control to terminal D of terminal block.

5.If meter does not indicate any voltage, then the diode is an open circuit or a wire harness has a broken wire. Test diode and wire harness for continuity.

6.If a short exists in the diode, all indicator lights will come on when one control is turned on.

7.Replace diode or light assembly as required.