Amana AK2T30/36E1/W1 Problems, Halogen Elements, Quick Star Element, Solid Disk Element

Models: AK2H30, AK2H36E2, AK2HW2 AK2T30/36E1/W1

1 47
Download 47 pages 4.51 Kb
Page 18
Image 18

Troubleshooting Procedures

Problems

 

Halogen Elements

 

Quick Star Element

 

Solid Disk Element

Element burns out

Improper wiring installation

Improper wiring installation

Improper wiring installation

immediately after

Hot Wired to Neutral

Hot Wired to Neutral

Hot Wired to Neutral

installation.

terminal. Warranty is

terminal. Warranty is

terminal. Warranty is

 

VOID.(SEE Installation

VOID.(SEE Installation

VOID.(SEE Installation

 

Instructions.)

Instructions.)

Instructions.)

 

NOTE: Possible damage to

NOTE: Possible damage to

NOTE: Possible damage to

 

glass.

glass.

glass.

 

 

 

 

Element fails to

1. Element is burned out or

1. Element is burned out.

1. Element is burned out.

heat; indicator light

 

halogen tube is open.

 

 

 

 

glows.

2.

Failed limit switch.

2.

Failed limit switch.

2.

Failed limit switch.

 

3.

Failed infinite switch.

3.

Failed infinite switch.

3.

Failed infinite switch.

 

 

 

 

Element too hot;

Runaway infinite switch or

Failed infinite or limit has

Failed infinite or limit has

no control of heat

limit has welded contacts.

welded contacts.

welded contacts.

at any setting.

 

 

 

 

 

 

 

 

 

 

Element too hot on

Failed limit switch.

Failed limit switch.

Failed limit switch.

HI setting only.

 

 

 

 

 

 

 

 

 

 

Erratic operation

Loose or broken wiring.

Loose or broken wiring.

Loose or broken wiring.

of surface

 

 

 

 

 

 

elements.

 

 

 

 

 

 

 

 

 

 

Indicator light

Infinite switch or hot light

Infinite switch or hot light

Failed infinite switch or

remains on when

switch fails:

switch fails:

diodes to indicator light.

control is turned

NOTE: In case where light

NOTE: In case where light

NOTE: In case where light

OFF or does not

does not light, could be failed

does not light, could be failed

does not light, could be failed

light when control

indicator light.

indicator light.

indicator light.

is turned ON.

 

 

 

 

 

 

 

 

 

 

Element making a

Caused by a 60 Hz AC

Caused by a 60 Hz AC

Caused by a 60 Hz AC

humming noise.

current passing through

current passing through

current passing through

 

element winding. Normal

element winding. Normal

element winding. Normal

 

occurrence does not affect

occurrence does not affect

occurrence does not affect

 

performance.

performance.

performance.

 

 

 

 

 

Metal rim next to

Does not apply

Does not apply

1.

Installation void in

heating element

 

 

 

 

 

element causing heat to

gets excessively

 

 

 

 

 

escape to rim area or

hot.

 

 

 

 

 

broken casting.

 

 

 

 

 

2.

Normal temperature is

 

 

 

 

 

 

approximately 200°F.

 

 

 

 

 

 

 

Runaway surface

1.

Faulty infinite switch.

1.

Faulty infinite switch.

1.

Faulty infinite switch.

control.

2.

Improperly wired.

2.

Improperly wired.

2.

Improperly wired.

 

 

 

 

 

Poor performance

1. Knobs on surface controls

1. Knobs on surface controls

1.

Knobs on surface

when unit is

 

indicating incorrect

 

indicating incorrect

 

controls indicating

installed.

 

setting. (knob set to HI

 

setting. (knob set to HI

 

incorrect setting. (knob

 

 

control is actually set on

 

control is actually set on

 

set to HI control is

 

 

LO.)

 

LO.)

 

actually set on LO.)

 

2. Improper wiring or switch

2. Improper wiring or switch

2. Improper wiring or switch

 

 

installation.

 

installation.

 

installation.

 

 

 

 

 

 

 

RS2420002 Rev. 5

18

Page 18
Image 18
Amana AK2T30/36E1/W1 Problems, Halogen Elements, Quick Star Element, Solid Disk Element, Troubleshooting Procedures