Amana VR8205 Figure Gas Inlet Through Furnace Left Side Upflow, Counterflow Installations

Models: VR8205

1 29
Download 29 pages 13.09 Kb
Page 14
Image 14
COUNTERFLOW INSTALLATIONS

When the gas piping enters through the left side of the furnace, the installer must supply the following fittings (starting from the gas valve):

Straight pipe to reach the exterior of the furnace (Fig- ures 14 & 15).

A ground joint union, drip leg, and manual shutoff valve must also be supplied by the installer. In some cases, the installer may also need to supply a transition piece from 1/2 inch to another pipe size.

COUNTERFLOW INSTALLATIONS

When the gas piping enters through the left side of the furnace, the installer must supply a straight pipe to reach the exterior of the furnace (Figure 17).

Figure 14

Gas Inlet Through Furnace Left Side

(Upflow)

Figure 15

Gas Inlet Through Furnace Top Side

(Upflow)

The gas piping connections shown in Figures 13 and 14 are for a furnace equipped for a right hand discharge. Adapta- tion for left hand discharge should be self explanatory.

Figure 16

Horizontal Furnace

(Right Hand Discharge)

Figure 17

Gas Inlet Through Left Side

(Counterflow)

A ground joint union, drip leg, and manual shutoff valve must also be supplied by the installer. In some cases, the installer may also need to supply a transition piece from 1/2" to another pipe size.

When the gas piping enters through the right side of the furnace, the installer must supply the following fittings (starting at the gas valve):

90 degree elbow.

Close nipple.

90 degree elbow.

Straight pipe to reach exterior of furnace (Figure 18).

A ground joint union, drip leg, and manual shutoff valve must also be supplied by the installer. In some cases, the installer may also need to supply a transition piece from 1/2 inch to another pipe size.

Figure 18

Gas Inlet Through Right Side

(Counterflow)

“Left side” and “right side” above are as viewed for a counterflow installation. Adaptation for horizontal airflow should be self explanatory.

14

Page 14
Image 14
Amana VR8205 Figure Gas Inlet Through Furnace Left Side Upflow, Figure Gas Inlet Through Furnace Top Side Upflow