Amana VR8205 Heating, Integrated Ignition Control, Diagnostic Signal Chart

Models: VR8205

1 29
Download 29 pages 13.09 Kb
Page 20
Image 20
Heating

Heating

Timing Chart for Integrated Ignition Control Normal Heating Operation

Induced Draft Blower

Gas Valve

Ignitor

Pressure Switch Combustion Blower

Thermostat

On

 

 

 

 

 

 

 

 

Off

 

 

 

 

 

 

 

 

Open

 

 

 

 

 

 

 

 

Closed

 

 

 

 

 

 

 

 

On

 

 

 

 

 

 

 

 

Off

 

 

 

 

 

 

 

 

Closed

 

 

 

 

 

 

 

 

Open

 

 

 

 

 

 

 

 

On

 

 

 

 

 

 

 

 

Off

 

 

 

 

 

 

 

 

On

 

 

 

 

 

 

 

 

Off

 

 

 

 

 

 

 

 

Seconds*

0

17

21

24

54

0

5

60, 90, 120,

 

 

 

 

 

 

 

or 15

or 180

* Timings may vary ±2 seconds.

Integrated Ignition Control

Diagnostic Signal Chart

 

 

 

Refer to Abnormal

Light Signal

 

Operation Number

Continuous Light

1

Internal Control Failure

1

Flash

2

System Lockout

2

Flashes

3

Pressure Switch Stuck Closed

3

Flashes

4

Pressure Switch Stuck Open

4

Flashes

5

Open Limit Control

5

Flashes

6

Open Rollout Control

Continuous Flashing

7

Flame Sensed No Call For Heat

 

 

 

 

Timing Chart for Normal Cooling Operation

Indoor Fan

On Off

Outdoor Fan

AndOn

CompressorOff

Thermostat

On Off

Seconds

0

45

20

Page 20
Image 20
Amana VR8205 Heating, Integrated Ignition Control, Diagnostic Signal Chart, Timing Chart for Normal Cooling Operation