Storage

Storage

This Portable AC features the

Innovative AutoDrain NanoMist Technology.

Very little excess water should accumulate. If any water accumulates, refer to “Emptying the Water Container” on page 9.

Drain the condensed water (if any) completely.

Clean or change the filter.

Put the unit on a warm day in fan mode for a couple of hours to ensure that the inside can dry out completely.

Store the power cable as shown, protect the unit against dust (put back into its original carton) and store in a dry place not accessible for children.

To protect the unit against dust, store in a dry place not accessible by children.

Do not stock heavy objects on top of the unit.

Troubleshooting

Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property.

Problem

Cause

Solution

 

 

 

The air

No power supply. Make sure the

Connect to a functioning outlet and switch on.

conditioner does

green light on the plug is lit.

 

not function.*

Is the power light flashing?

Empty the drain pan.

 

Is the water full LED lit?

 

The air

The unit is in direct sunlight.

Close curtains.

conditioner does

Windows or doors open, many

Close doors and windows, place an extra air

not seem to

people or a heat source in the room.

conditioner.

perform.

The filter is dirty.

Clean or replace the filter.

 

Air inlet or air outlet blocked.

Remove the blockage.

 

Room temperature lower than the

Change temperature selection.

 

selected value.

Set at the lowest possible setting: 62°C.

The unit is noisy.

Unit stands uneven.

Place on an even, solid surface (less vibrations).

The compressor

The overheat protection may be

Wait 30 minutes until the temperature has

does not work.

activated.

decreased, then turn on the unit again.

The remote

Distance too great.

Make sure the remote control is correctly

control does not

Remote control signal not detected

aimed at the control panel.

function.

by the control panel.

 

 

The batteries are drained.

Replace the batteries.

 

 

 

*If you plug in the Air Conditioner, and there is no green light on the plug, press the reset button on the LCDI plug. The green light should be lit, indicating that the air conditioner is getting power from the electrical outlet.

If the plug continues to trip (which is a USA national safety standard feature) and the green light goes off, the cord may be damaged preventing you from resetting the unit. For your safety, contact a licensed electrician.

RESET

TEST

Reset Button Test Button