American Aldes RDF 8-8IP installation instructions Mounting Bracket Locations, Electrical Data

Models: RDF 8-8IP

1 6
Download 6 pages 27 b
Page 6
Image 6
ELECTRICAL DATA

operation. The entire motor and fan assembly is mounted on a drop-down hinged access panel for service and inspection, and can be removed from the fan without disassembly of the ducting connections.

Controls: The fans can be operated manually, or automatically by a programmable timer or dehumidistat and may also be operated in conjunction with a variable speed control.

Locating and Installing the Fan: The compact dimensions and versatile mounting options permit installation above drop ceilings, between ceiling joists, or within a small soffit location. The fan can be installed either horizontally or vertically.

Airflow Balancing: The flow rates are automatically set with preset ALDES Constant Airflow Regulators.

A passively controlled element in each duct run inflates or deflates automatically in response to system pressure to maintain constant airflow.

ELECTRICAL DATA

MPVS 100 / 120

120 V, 60 Hz., .19/.29 amp.,

22/38 W Max., 2980 / 3135 RPM

Above ratings are intended for sizing electrical wring only. Actual consumption will be lower.

MOUNTING BRACKET

LOCATIONS

TABLE OF AIRFLOWS AND DUCT LENGHTS*

 

3" INTAKE DUCT TO FAN

 

Recommended

 

Max. Duct Length from

AIRFLOW

Grille to Fan (ft.)

CFM

SMOOTH

FLEXIBLE

10

225

180

20

65

50

30

30

25

 

 

 

40**

20

15

50**

10

10

 

FAN DISCHARGE DUCT

FOR EACH

TOTAL

Assumes low pressure drop

vent cap

 

ELBOW

EXHAUST

 

 

 

 

DEDUCT

RATE CFM

4" SMOOTH

4" FLEXIBLE

 

60

40 ft

 

20 ft

 

75

25 ft

 

15 ft

 

90

18 ft

 

12 ft

3" Diameter

100

15 ft

 

9 ft

= 3 Feet

120

11 ft

 

8 ft

 

135

8 ft

 

6 ft

 

*This table should only be used as a general guide. Actual duct length allowances may be longer on some models. Contact the factory for assistance. **CAR Flow Regulators not available over 35 cfm. NOTE: If longer duct runs are required than permitted in the table above, use smooth ducting and/or increase the diameter.

BRADENTON, FL 34203

P:941.351.3441

F:

941.351.3442

 

E:

info@aldes-us.com

www.americanaldes.com

 

 

02/09

Page 6
Image 6
American Aldes RDF 8-8IP Mounting Bracket Locations, Electrical Data, Table Of Airflows And Duct Lenghts