4) HSI (Hot Surface Ignition) 24 VAC Redundant Gas Valve
IMPORTANT: The HSI 24 VAC Redundant Gas Valve contain no serviceable parts.
REPLACEMENT COILS ARE NOT AVAILABLE.
IMPORTANT: THERE ARE NO PARTS AVAILABLE FOR FIELD REPAIR. Replace gas valve only with exact model and/or type number as noted on gas valve.
a)The redundant gas valve utilize 24 VAC, which is provided by the HSI module.
(1)To check the resistance value;
(a)Disconnect the terminations at the gas valve from the HSI module.
WARNING: When taking ohm readings, the terminations from the HSI module must be disconnected/removed, otherwise, the readings obtained will be incorrect and/or erroneous.
36E Redundant Gas Valve
(2)With a meter (either a multimeter or ohmmeter) set on the 200 ohm position, place the meter leads across:
(a)Terminals 1 and 2...the reading should be approximately 96 ohms +/- 5 ohms.
(b)Terminals 2 and 3...the reading should be approximately 96 ohms +/- 5 ohms also.
(3)If, after checking the resistance values on the gas valve it is determined that the ohm readings do not approximate the ohm values listed above (96 ohms [+/- 5 ohms] for both readings respectively), then, the gas valve must be replaced.