2.Technical Data

a. Gas Specifications

 

TYPE OF GAS

 

 

 

 

 

 

 

NATURAL

LIQUID PROPANE

 

 

 

 

 

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

 

 

 

 

 

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

 

 

 

 

 

Shaded areas are stated in metric equivalents

b.Gas Connections:

Inlet connection ---------- 1-1/2” N.P.T.

Inlet supply size ---------- 1-1/2” N.P.T. (minimum) Btu/hr input (per dryer) - 550,000 (138,600 kcal/hr)

1)Natural Gas

Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water column (W.C.) pressure.

2)Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

 

 

 

 

TYPE OF GAS

 

L.P.

 

 

 

 

 

 

 

 

 

Conversion

MODEL

BTU

Kcal/hr

 

Natural

 

Liquid Propane

 

 

Kit

Per Hour

 

 

Part

 

 

Part

NUMBER

Rating

Qty.

D.M.S.*

Qty.

D.M.S.*

Part Number

 

Rating

 

Number

Number

ID-170

550,000

138,600

4

#2

140839

3

#29

140820

883111

 

 

 

 

 

 

 

 

 

 

Shaded area is stated in metric equivalent.

*Drill Materical Size (D.M.S.) equivalents are as follows:

Natural Gas ................. #2 = .2210” (5.61 mm) Liquid Propane Gas .... #29 = .1360” (3.45 mm)

27

Page 31
Image 31