4.Steam Damper Air System Connections

The IDS-170 is manufactured with a pneumatic (piston) damper system which requires an external supply of compressed air. The air connection is made to the steam damper solenoid valve which is located at the rear inner top area of the dryer just in front of the electric service relay box. (Refer to the bottom illustration on page 33).

a. Air Requirements

COMPRESSED

AIR PRESSURE

AIR SUPPLY

 

 

 

 

 

Normal

80 PSI

5.51 bars

 

 

 

Minimum Supply

70 PSI

4.82 bars

 

 

 

Maximum Supply

90 PSI

6.21 bars

 

 

 

Shaded areas are stated in metric equivalents

b.Air Connection

Air connection to system --- 1/8-inch N.P.T.

c.No air regulator or filtration is provided with the dryer. External regulation/filtration of 3.25 cfh (0.09 cmh) at 80 PSI (5.51 bars) must be provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed air line just before the dryer connection. This is necessary to insure that correct and clean air pressure is achieved.

5.Steam Damper System Operation

The IDS-170 steam damper as shown in the top illustration on page 33, allows the coil to stay constantly charged eliminating repeated expansion and contraction. When the damper is opened, the air immediately passes through the already hot coil, providing instant heat to start the drying process. When the damper is closed, ambient air is drawn directly into the basket (tumbler), allowing a rapid cool down.

Diagram 1 shows the damper in the heating (open) mode, allowing heat into the basket (tumbler).

Diagram 2 shows the damper in the cool down (closed) mode, pulling ambient air directly into the basket (tumbler) without passing through the coils.

NOTE: With the dryer off or with no air supply, the steam damper is in cool down mode as shown in Diagram 2 at the top of page 33.

32

Page 36
Image 36
American Dryer Corp ID-170 installation manual Compressed AIR Pressure