C. DRYER ENCLOSURE REQUIREMENTS

Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of 12-inches (30.48 cm) above the dryer’s outer top; except along the front of the dryer, which may be closed if desired.

NOTE: Allowances must be made for opening the control door.

NOTE: With the exception of the floor, clearances shown are for combustible construction.

X= 12-inch (30.48 cm) minimum, 24-inches (60.96 cm) is suggested for ease of maintenance. * 1-inch (2.54 cm) maximum for electric dryers.

NOTE: Air considerations are important for proper and efficient operation.

Dryers may be positioned sidewall to sidewall. However, a 1/16-inch (1.59 mm) minimum allowance must be made for opening and closing of the control door. It is suggested that the dryer be positioned about 2 feet (0.61 meters) away from the nearest obstruction for ease of installation, maintenance, and service (to be measured from the back guard). Refer to the illustration above for details.

10

Page 14
Image 14
American Dryer Corp MDG30V installation manual Dryer Enclosure Requirements