American Dryer Corp ML-55HS Procedure for Functional Check Replacement Components

Models: ML-55HS

1 56
Download 56 pages 61.68 Kb
Page 48
Image 48

SECTION VII

PROCEDURE FOR FUNCTIONAL CHECK

OF REPLACEMENT COMPONENTS

1.Microprocessor Controller (Computer) Board

a.Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer.

b.Start the drying cycle by pressing any of the preset cycles in letters A-F.

c.Verify that the motor(s) and the heat indicator dots, in the microprocessor controller (computer) light emitting diode (L.E.D.) display are on. (Refer to the illustration below.)

1.Basket (tumbler) in Forward Mode (clockwise [CW]).

2.Basket (tumbler) in Reverse Mode (counterclockwise [CCW]) indicator (for reversing models only).

3.Heat on indicator.

4.On indicator (dryer is in operation mode).