2.ELECTRICAL SERVICE SPECIFICATIONS A. Gas and Steam Models

MLG-75 (Gas)

MLS-75 (Steam)

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTE: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.

B.Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3Ø dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX.

MINIMUM

FUSING

CIRCUIT

Dual Element

VOLTAGE

SERVICE

AMP DRAW

WIRE SIZE*

BREAKER

 

 

 

 

 

 

Time Delay

 

120

(60 Hz)

1

2

13

10

20

25

 

 

 

 

 

 

 

 

208

(60 Hz)

1

2

8

14

12

15

 

 

 

 

 

 

 

 

208

(60 Hz)

3

3/4

5

14

8

15

 

 

 

 

 

 

 

 

240

(50/60 Hz)

3

3/4

5

14

8

15

 

 

 

 

 

 

 

 

240

(50/60 Hz)

1

2

7

14

12

15

 

 

 

 

 

 

 

 

380-400

(50 Hz)

3

3/4

3

14

5

15

 

 

 

 

 

 

 

 

416

(50 Hz)

3

3/4

3

14

5

15

 

 

 

 

 

 

 

 

460

(60 Hz)

3

3/4

3

14

5

15

 

 

 

 

 

 

 

 

* AWG Stranded Wire ... for individual lenghts less than 100 feet.

IMPORTANT: Figures shown are for non-reversing models ONLY. For reversing models contact the factory.

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the back side of the upper/top control door. In the case of 208 VAC or 230/240 VAC, the supply voltage must match the electric service specifications of the data label exactly.

IMPORTANT: The wire size must be properly sized to handle the related current.

WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or obligation.