B. Electric Models Only

MLE-75 (Electric)

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTE: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.

B.Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C . Circuit breakers for 3Ø dryers must be 3-pole type.

KW

20

24

30

33

36

40

AMP DRAW

APPROX.

APPLIED VOLTAGE/PHASE

208/1ø (60 Hz)

240/1ø (50/60 Hz)

208/3ø (50/60 Hz)

240/3ø (50/60 Hz)

380/3ø (50 Hz)

416/3ø (50 Hz)

460/3ø (60 Hz)

105

90

---

-- -

33

---

---

-- -

---

72

63

-- -

36

33

-- -

---

88

77

-- -

45

41

-- -

---

---

-- -

53

---

---

-- -

---

104

92

-- -

53

48

-- -

---

---

-- -

-- -

59

---

 

 

 

 

 

 

 

IMPORTANT: Figures shown are for non-reversing models ONLY. For reversing models contact the factory.

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the back side of the upper/top control door. In the case of 208 VAC or 230/240 VAC, the supply voltage must match the electric service specifications of the data label exactly.

IMPORTANT: The wire size must be properly sized to handle the related current.

WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or obligation.

IMPORTANT: 3 phase figures shown are for a 3 wire service ONLY.

21

Page 25
Image 25
American Dryer Corp ML-75HS installation manual MLE-75 Electric, Electric Models Only