IMPORTANT: Dryer blower motor impellor/fan as viewed from the front must turn in the clockwise (CW) direction, otherwise the dryer efficiency will be drastically reduced and premature component failure can result.
5.Heat Circuit Operational Test a. Gas Models
1)When the dryer is first started (during initial
2)The dryer is equipped with a Hot Surface Ignition (HSI) system which has internal diagnostics. If ignition is not established after three (3) attempts, the heat circuit HSI module will LOCKOUT until it is manually reset. To reset the HSI system, open and close the main door and restart the dryer (press the “ENTER/START” key).
NOTE: During the purging period, check to be sure that ALL gas
3)Once ignition is established, a gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the water column (W.C.) pressure is correct and consistent.
NOTE: Water column pressure requirements (measured at the gas valve pressure tap)...
Natural Gas | 3.5 Inches W.C. (8.7 mb). |
L.P. | 10.5 Inches W.C. (26.1 mb). |
IMPORTANT: There is no regulator provided in an L.P. dryer. The water column (W.C.) pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.
6.Make a complete operational check of ALL
NOTE: To check for proper sail switch operation, open the main door and while holding main door switch plunger in, start the dryer. The dryer should start but the heat circuit should not be activated (on). If the heat (burner) does activate, shut the dryer off and make the necessary adjustments.
7.A reversing tumbler (basket) dryer should never be operated with less than a 60 lb. (2.72 kg) load (dry weight). The size of the load will affect the
a. Microprocessor (computer) Dryer Models
1)Spin and stop are not adjustable in the Automatic Mode and have been preprogrammed into the microprocessor controller (computer) for
28