2.Technical Gas Data a. Gas Specifications
| TYPE OF GAS |
|
|
|
| ||||
|
|
|
|
|
|
|
| ||
| NATURAL |
| LIQUID PROPANE |
| |||||
|
|
|
|
|
|
|
|
| |
Manifold Pressure* | 3.5 inches W.C. | 8.7 mb |
| 10.5 inches W.C. |
| 26.1 mb |
| ||
|
|
|
|
|
|
|
|
| |
6.0 - 12.0 inches W.C. | 14.92 - 29.9 mb | 11.0 inches W.C. |
| 27.4 mb |
| ||||
|
|
|
|
|
|
|
|
|
|
Shaded areas are stated in metric equivalents |
|
|
|
|
|
|
|
| |
* Measured at gas valve pressure tap when gas valve is on. |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| ||||
Gas Inlet Size (Each Basket [Tumbler]) |
| 1/2” F.N.P.T. |
|
| |||||
|
|
|
|
|
| ||||
Btu/hr Input (Each Basket [Tumbler]) |
| 68,000 |
| 17,136 kcal/hr |
| ||||
|
|
|
|
| |||||
Btu/hr Input (Total for Both Baskets [Tumblers]) | 136,000 |
| 34,272 kcal/hr |
| |||||
|
|
|
|
|
|
|
|
|
|
F.N.P.T. = Female National Pipe Thread
b.Natural Gas
Regulation is controlled by each gas valve’s internal regulator. Incoming supply pressure must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water column (W.C.) pressure.
c.Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.
Maytag | 21 |