c.Lint Drawer Proximity Switches
The “Lint Drawer Proximity Switches” are located on the left side of the
NOTE: Front and Rear Drawers are not interchangeable.
“B” is used as an electrical interlock to the PLC’s 110 VAC output power
d.Lint Chamber Pressure Switch
The “Lint Chamber Pressure Sensing Switch” is located on the left rear side of the
2.0Tumbler Tilt Problems “LEVEL FAULT”
A “LEVEL FAULT” message is generated by the incorrect state of either the FRONT or REAR sensor switches. The following information will address the “LEVEL” signals, since they are associated with the Base Electrical Junction Box.
a.PROBABLE CAUSES;
1)WIRING BACK TO THE PLC (Programmable Logic Controller)
b.PROBABLE SOLUTIONS;
1)For a quick check of the FRONT DOWN and REAR DOWN signals to the PLC (Programmable Logic Controller) perform the following:
FRONT DOWN signal test procedure 1a REAR DOWN signal test procedure 1b
1a) Place the
•Actuate the Front Down switch by hand
•Have someone verify that PLC (Programmable Logic Controller) input #11 lights when the switch actuator is down, and is OFF when the actuator is up.
•Does L.E.D. #11 come “ON” when the switch is down?
• If “YES,” wiring is okay
64