ELECTRIC SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTE: A.

Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5

ONLY.

B.

Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct

 

breaker size according to appliance amp draw rating and type of breaker used.

 

 

C .

Circuit breakers for 3-phase dryers

must be 3-pole type.

 

 

 

 

 

 

 

 

 

 

 

 

 

SERVICE

 

WIRE

 

APPROX. AMP

FUSING

 

CIRCUIT

PHASE

 

DRAW

 

 

 

 

VOLTAGE

 

SERVICE

 

60 HZ

50 HZ

Dual Element

 

BREAKER

 

 

 

 

 

Time Delay

 

 

 

 

 

 

 

 

 

 

 

120

 

2

 

13

---

17.5

 

25

208

 

2

 

7.6

---

12

 

15

230/240

 

2

 

7

4.9

12

 

15

208

 

3

 

4.8

---

6.25

 

15

230/240

 

3

 

5

5.5

6.25

 

15

380

 

3/4

 

---

3

5

 

15

416

 

3/4

 

---

3.1

5

 

15

460/480

 

3/4

 

2.8

---

4.5

 

15

575

 

3

 

2.5

---

4.5

 

15

SUPER ADG-30DS (Gas) REVERSING

SUPER ADS-30DS (Steam) REVERSING

ELECTRIC SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT:

 

208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTE: A.

Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5

ONLY.

 

B.

Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker

 

size according to appliance amp draw rating and type of breaker used.

 

 

 

C.

Circuit breakers for 3-phase dryers must be 3-pole type.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SERVICE

 

 

WIRE

APPROX. AMP

FUSING

CIRCUIT

 

PHASE

DRAW

 

 

 

 

 

VOLTAGE

 

 

SERVICE

60 HZ

 

50 HZ

Dual Element

BREAKER

 

 

 

 

 

 

Time Delay

 

 

 

 

 

 

 

 

 

 

208

 

 

3

4.8

 

---

 

6.25

15

230/240

 

 

3

5

 

5.5

 

6.25

15

380

 

 

3/4

---

 

3

 

5

15

416

 

 

3/4

---

 

3.1

 

5

15

460/480

 

 

3/4

2.8

 

---

 

4.5

15

575

 

 

3

2.5

 

---

 

4.5

15

NOTE: Contact Factory for electrical information not listed.