American Dryer Corp Super AD-30 manual Troubleshooting, No L.E.D. light emitting diode display

Models: Super AD-30

1 63
Download 63 pages 57.5 Kb
Page 48
Image 48

SECTION VII

TROUBLESHOOTING

IMPORTANT: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GAS SUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS

or GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, or TESTING OF ANY EQUIPMENT per OSHA (Occupational Safety and Health Administration)

STANDARDS.

The information provided will help isolate the most probable component(s) associated with the difficulty described. The experienced technician realizes, however, that a loose connection or broken/ shorted wire may be at fault where electrical components are concerned ... and not necessarily the suspected component itself.

Electrical parts should always be checked for failure before being returned to the factory.

The information provided should not be misconstrued as a handbook for use by an untrained person making repairs.

IMPORTANT: When replacing blown fuses, the replacement must be of the exact rating as the fuse being replaced.

WARNING: ALL SERVICE and TROUBLESHOOTING SHOULD BE PERFORMED BY A QUALIFIED PROFESSIONAL OR SERVICE AGENCY.

WARNING: WHILE MAKING REPAIRS, OBSERVE ALL SAFETY PRECAUTIONS DISPLAYED ON THE DRYER or SPECIFIED IN THIS MANUAL.

MICROPROCESSOR (COMPUTER) MODELS

A.No L.E.D. (light emitting diode) display...

1.Service panel fuse blown or tripped breaker.

2.Blown control circuit L1 or L2 1/2-amp (Slo Blo) fuse.

3.Failed microprocessor controller (computer).

4.Failed step down transformer (for models 380 volts or higher Only).

B.Drive motor not operating (does not start)...

1.Failed drive motor contactor (relay).

2.Failed arc suppressor (A.S.) board (for Reversing Models Only).

3.Failed drive motor.

44

Page 48
Image 48
American Dryer Corp Super AD-30 manual Troubleshooting, No L.E.D. light emitting diode display