American Dryer Corp T20 Warning Gas Models Only, Electrical Service Specifications, Term, High

Models: T20 T30

1 32
Download 32 pages 56.34 Kb
Page 18
Image 18
Warning (Gas Models Only)

Warning (Gas Models Only)

!Dryers built for use with a voltage between 200 and 240 must verify the input voltage during

installation. If the nominal voltage is outside of the medium tolerances shown on the diagram below, adjust the autotransformer, located

near the burner assembly.

To adjust the

TERM

LINE VOLTAGE

autotransformer wiring,

 

 

50 Hz

60 Hz

 

place the red wire on the

 

 

 

HIGH

260

283

appropriate tap (HIGH, MED,

226

249

LOW) of the

 

 

 

 

 

239

260

autotransformer. For

MED

208

230

additional wiring details,

 

refer to the electrical

LOW

217

236

diagram located on the

189

208

 

inside of the control panel.

 

 

 

 

 

 

Electrical Service Specifications

Gas Models Only

ELECTRICAL SERVICE SPECIFICATIONS

IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES:

A.

When fuses are used they must be dual element, time delay, current limiting,

 

 

class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying

 

 

either local and/or National Electrical Codes to listed appliance amp draw data.

 

B.

Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY.

 

 

For others, calculate/verify correct breaker size according to appliance amp

 

 

draw rating and type of breaker used.

 

C.

Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

 

WIRE

APPROX.

CIRCUIT

PHASE

AMP DRAW

VOLTAGE

SERVICE

BREAKER

 

60 Hz

50 Hz

 

 

 

 

 

 

T20

 

 

 

120

2

8.9

15

200

2

7.7

7.8

15

208

2

7.6

15

220

2

7.4

15

230

2

7.3

15

240

2

7.2

7.0

15

 

 

T30

 

 

 

120

2

10.3

15

200

2

8.7

8.8

15

208

2

8.4

15

220

2

8.1

8.1

15

230

2

7.4

15

240

2

7.7

7.0

15

 

 

T50

 

 

 

120

2

15.6

20

200

2

10.5

20

208

2

10.5

20

220

2

10.0

10.7

20

230

2

10.8

20

240

2

9.7

20

 

 

T75

 

 

 

120

2

15.6

20

200

2

10.5

20

208

2

10.5

20

220

2

10.0

10.7

20

230

2

10.8

20

240

2

9.7

20

7/15/08

Steam Models Only

ELECTRICAL SERVICE SPECIFICATIONS

IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES:

A.

When fuses are used they must be dual element, time delay, current limiting,

 

 

class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying

 

 

either local and/or National Electrical Codes to listed appliance amp draw data.

 

B.

Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY.

 

 

For others, calculate/verify correct breaker size according to appliance amp

 

 

draw rating and type of breaker used.

 

C.

Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

 

WIRE

APPROX.

CIRCUIT

PHASE

AMP DRAW

VOLTAGE

SERVICE

BREAKER

 

60 Hz

50 Hz

 

 

 

 

 

 

T30

 

 

 

120

2

9.3

15

208

2

6.2

6.0

15

220

2

5.6

5.5

15

230

2

5.4

15

240

2

5.1

15

 

 

T50

 

 

 

120

2

14.4

20

200

2

8.2

20

208

2

8.2

20

220

2

7.8

8.4

20

230

2

8.5

20

240

2

7.6

20

 

 

T75

 

 

 

120

2

14.4

20

200

2

8.2

20

208

2

8.2

20

220

2

7.8

8.4

20

230

2

8.5

20

240

2

7.6

20

7/15/08

NOTES ______________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

_____________________________________________________________

18

JLA Limited

113429 - 9

Page 18
Image 18
American Dryer Corp T20 Warning Gas Models Only, Electrical Service Specifications Gas Models Only, Term, Line Voltage