Heat Input/Gas Consumption/Orifice (Injector) Data (For Non CE [European] Models Only)

Gas Specifications for Non-CE Approved Dryers**

Model

Gas

Nominal

Supply

Gross

Orifice Size

Orifice

Burner

Heating Value

Pressure

Heat Input

 

 

(Injector)

Pressure

 

Type

 

 

 

 

 

 

Quantity

 

 

Btu/ft3

in wc

Btu/hr

kW

DMS

mm

in wc

 

 

T20

Natural

1,000

7.0-13.0

40,000

11.72

30

3.264

1

3.0

*Liquid Propane

2,500

11.0

40,000

11.72

49

1.854

1

10.0

 

T30

Natural

1,000

7.0-13.0

55,000

16.12

20

4.089

1

3.0

*Liquid Propane

2,500

11.0

55,000

16.12

44

2.184

1

10.0

 

T50

Natural

1,000

7.0-13.0

90,000

26.38

29

3.454

2

3.0

*Liquid Propane

2,500

11.0

90,000

26.38

47

2.994

2

10.0

 

T75

Natural

1,000

7.0-13.0

110,000

32.24

22

3.988

2

3.0

*Liquid Propane

2,500

11.0

110,000

32.24

44

2.184

2

10.0

 

Shaded areas are stated in metric equivalents

*Gas valve’s internal regulator disabled.

**Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

Heat Input/Gas Consumption/Orifice (Injector) Data (For CE [European] Models Only)

Gas Specifications for CE Approved Dryers**

 

Gas

Nominal

Supply

Gross

Fuel

Orifice Size

Orifice

Burner

Model

Heating Value

Pressure

Heat Input

(Injector)

Pressure

Type

Consumption

 

 

 

 

 

 

 

 

 

Quantity

 

 

 

Btu/ft3

mb

Btu/hr

kW

 

DMS

mm

mb

 

Natural (I2 H/I2E )

1,000

15-30

40,000

11.72

1.133 M3/H

30

3.264

1

6.7

 

Natural (I2 L )

830

20-35

40,000

11.72

1.365 M3/H

30

3.264

1

9.2

 

Natural (I2 E L L )

830

15-30

40,000

11.72

1.365 M3/H

30

3.264

1

9.2

T20

*Natural (I2E+)

1,000

20

40,000

11.72

1.133 M3/H

38

2.578

1

830

25

40,000

11.72

1.365 M3/H

38

2.578

1

 

 

*Butane (I3+)

3,175

28-30

40,000

11.72

0.845 kg/H

52

1.613

1

 

*Propane (I3 +)

2,500

37

40,000

11.72

0.845 kg/H

52

1.613

1

 

Butane (I3 B /P )

3,175

28-30/50

40,000

11.72

0.845 kg/H

49

1.854

1

18.0

 

Propane (I3 P )

2,500

28-30/50

40,000

11.72

0.845 kg/H

49

1.854

1

23.0

 

Natural (I2 H/I2E )

1,000

15-30

55,000

16.12

1.557 M3/H

22

3.988

1

6.9

 

Natural (I2 L )

830

20-35

55,000

16.12

1.876 M3/H

22

3.988

1

9.5

 

Natural (I2 E L L )

830

15-30

55,000

16.12

1.876 M3/H

22

3.988

1

9.5

 

*Natural (I2E+)

1,000

20

55,000

16.12

1.557 M3/H

31

3.048

1

T30

830

25

55,000

16.12

1.876 M3/H

31

3.048

1

 

 

*Butane (I3+)

3,175

28-30

55,000

16.12

1.162 kg/H

48

1.930

1

 

*Propane (I3 +)

2,500

37

55,000

16.12

1.162 kg/H

48

1.930

1

 

Butane (I3 B /P )

3,175

28-30/50

55,000

16.12

1.162 kg/H

44

2.184

1

18.1

 

Propane (I3 P )

2,500

28-30/50

55,000

16.12

1.162 kg/H

44

2.184

1

24.9

 

Natural (I2 H/I2E )

1,000

15-30

90,000

26.38

2.549 M3/H

29

3.454

2

7.2

 

Natural (I2 L )

830

20-35

90,000

26.38

3.071 M3/H

29

3.454

2

8.9

 

Natural (I2 E L L )

830

15-30

90,000

26.38

3.071 M3/H

29

3.454

2

8.9

 

*Natural (I2E+)

1,000

20

90,000

26.38

2.549 M3/H

35

2.794

2

T50

830

25

90,000

26.38

3.071 M3/H

35

2.794

2

 

 

*Butane (I3+)

3,175

28-30

90,000

26.38

1.901 kg/H

50

1.778

2

 

*Propane (I3 +)

2,500

37

90,000

26.38

1.901 kg/H

50

1.778

2

 

Butane (I3 B /P )

3,175

28-30/50

90,000

26.38

1.901 kg/H

47

1.994

2

18.1

 

Propane (I3 P )

2,500

28-30/50

90,000

26.38

1.901 kg/H

47

1.994

2

24.9

 

Natural (I2 H/I2E )

1,000

15-30

110,000

32.24

3.115 M3/H

22

3.988

2

6.9

 

Natural (I2 L )

830

20-35

110,000

32.24

3.753 M3/H

22

3.988

2

9.5

 

Natural (I2 E L L )

830

15-30

110,000

32.24

3.753 M3/H

22

3.988

2

9.5

 

*Natural (I2E+)

1,000

20

110,000

32.24

3.115 M3/H

31

3.048

2

T75

830

25

110,000

32.24

3.753 M3/H

31

3.048

2

 

 

*Butane (I3+)

3,175

28-30

110,000

32.24

2.324 kg/H

48

1.930

2

 

*Propane (I3 +)

2,500

37

110,000

32.24

2.324 kg/H

48

1.930

2

 

Butane (I3 B /P )

3,175

28-30/50

110,000

32.24

2.324 kg/H

44

2.184

2

18.1

 

Propane (I3 P )

2,500

28-30/50

110,000

32.24

2.324 kg/H

44

2.184

2

24.9

Shaded areas are stated in metric equivalents

*Gas valve’s internal regulator disabled.

**Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

22

JLA Limited

113429 - 9

Page 22