Heat Input/Gas Consumption/Orifice (Injector) Data (For Non CE [European] Models Only)
Gas Specifications for
Model | Gas | Nominal | Supply | Gross | Orifice Size | Orifice | Burner | |||
Heating Value | Pressure | Heat Input |
|
| (Injector) | Pressure | ||||
| Type |
|
|
|
|
|
| Quantity |
| |
| Btu/ft3 | in wc | Btu/hr | kW | DMS | mm | in wc | |||
|
| |||||||||
T20 | Natural | 1,000 | 40,000 | 11.72 | 30 | 3.264 | 1 | 3.0 | ||
*Liquid Propane | 2,500 | 11.0 | 40,000 | 11.72 | 49 | 1.854 | 1 | 10.0 | ||
| ||||||||||
T30 | Natural | 1,000 | 55,000 | 16.12 | 20 | 4.089 | 1 | 3.0 | ||
*Liquid Propane | 2,500 | 11.0 | 55,000 | 16.12 | 44 | 2.184 | 1 | 10.0 | ||
| ||||||||||
T50 | Natural | 1,000 | 90,000 | 26.38 | 29 | 3.454 | 2 | 3.0 | ||
*Liquid Propane | 2,500 | 11.0 | 90,000 | 26.38 | 47 | 2.994 | 2 | 10.0 | ||
| ||||||||||
T75 | Natural | 1,000 | 110,000 | 32.24 | 22 | 3.988 | 2 | 3.0 | ||
*Liquid Propane | 2,500 | 11.0 | 110,000 | 32.24 | 44 | 2.184 | 2 | 10.0 | ||
|
Shaded areas are stated in metric equivalents
*Gas valve’s internal regulator disabled.
**Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Heat Input/Gas Consumption/Orifice (Injector) Data (For CE [European] Models Only)
Gas Specifications for CE Approved Dryers**
| Gas | Nominal | Supply | Gross | Fuel | Orifice Size | Orifice | Burner | |||
Model | Heating Value | Pressure | Heat Input | (Injector) | Pressure | ||||||
Type | Consumption |
|
| ||||||||
|
|
|
|
|
|
| Quantity |
| |||
|
| Btu/ft3 | mb | Btu/hr | kW |
| DMS | mm | mb | ||
| Natural (I2 H/I2E ) | 1,000 | 40,000 | 11.72 | 1.133 M3/H | 30 | 3.264 | 1 | 6.7 | ||
| Natural (I2 L ) | 830 | 40,000 | 11.72 | 1.365 M3/H | 30 | 3.264 | 1 | 9.2 | ||
| Natural (I2 E L L ) | 830 | 40,000 | 11.72 | 1.365 M3/H | 30 | 3.264 | 1 | 9.2 | ||
T20 | *Natural (I2E+) | 1,000 | 20 | 40,000 | 11.72 | 1.133 M3/H | 38 | 2.578 | 1 | — | |
830 | 25 | 40,000 | 11.72 | 1.365 M3/H | 38 | 2.578 | 1 | — | |||
| |||||||||||
| *Butane (I3+) | 3,175 | 40,000 | 11.72 | 0.845 kg/H | 52 | 1.613 | 1 | — | ||
| *Propane (I3 +) | 2,500 | 37 | 40,000 | 11.72 | 0.845 kg/H | 52 | 1.613 | 1 | — | |
| Butane (I3 B /P ) | 3,175 | 40,000 | 11.72 | 0.845 kg/H | 49 | 1.854 | 1 | 18.0 | ||
| Propane (I3 P ) | 2,500 | 40,000 | 11.72 | 0.845 kg/H | 49 | 1.854 | 1 | 23.0 | ||
| Natural (I2 H/I2E ) | 1,000 | 55,000 | 16.12 | 1.557 M3/H | 22 | 3.988 | 1 | 6.9 | ||
| Natural (I2 L ) | 830 | 55,000 | 16.12 | 1.876 M3/H | 22 | 3.988 | 1 | 9.5 | ||
| Natural (I2 E L L ) | 830 | 55,000 | 16.12 | 1.876 M3/H | 22 | 3.988 | 1 | 9.5 | ||
| *Natural (I2E+) | 1,000 | 20 | 55,000 | 16.12 | 1.557 M3/H | 31 | 3.048 | 1 | — | |
T30 | 830 | 25 | 55,000 | 16.12 | 1.876 M3/H | 31 | 3.048 | 1 | — | ||
| |||||||||||
| *Butane (I3+) | 3,175 | 55,000 | 16.12 | 1.162 kg/H | 48 | 1.930 | 1 | — | ||
| *Propane (I3 +) | 2,500 | 37 | 55,000 | 16.12 | 1.162 kg/H | 48 | 1.930 | 1 | — | |
| Butane (I3 B /P ) | 3,175 | 55,000 | 16.12 | 1.162 kg/H | 44 | 2.184 | 1 | 18.1 | ||
| Propane (I3 P ) | 2,500 | 55,000 | 16.12 | 1.162 kg/H | 44 | 2.184 | 1 | 24.9 | ||
| Natural (I2 H/I2E ) | 1,000 | 90,000 | 26.38 | 2.549 M3/H | 29 | 3.454 | 2 | 7.2 | ||
| Natural (I2 L ) | 830 | 90,000 | 26.38 | 3.071 M3/H | 29 | 3.454 | 2 | 8.9 | ||
| Natural (I2 E L L ) | 830 | 90,000 | 26.38 | 3.071 M3/H | 29 | 3.454 | 2 | 8.9 | ||
| *Natural (I2E+) | 1,000 | 20 | 90,000 | 26.38 | 2.549 M3/H | 35 | 2.794 | 2 | — | |
T50 | 830 | 25 | 90,000 | 26.38 | 3.071 M3/H | 35 | 2.794 | 2 | — | ||
| |||||||||||
| *Butane (I3+) | 3,175 | 90,000 | 26.38 | 1.901 kg/H | 50 | 1.778 | 2 | — | ||
| *Propane (I3 +) | 2,500 | 37 | 90,000 | 26.38 | 1.901 kg/H | 50 | 1.778 | 2 | — | |
| Butane (I3 B /P ) | 3,175 | 90,000 | 26.38 | 1.901 kg/H | 47 | 1.994 | 2 | 18.1 | ||
| Propane (I3 P ) | 2,500 | 90,000 | 26.38 | 1.901 kg/H | 47 | 1.994 | 2 | 24.9 | ||
| Natural (I2 H/I2E ) | 1,000 | 110,000 | 32.24 | 3.115 M3/H | 22 | 3.988 | 2 | 6.9 | ||
| Natural (I2 L ) | 830 | 110,000 | 32.24 | 3.753 M3/H | 22 | 3.988 | 2 | 9.5 | ||
| Natural (I2 E L L ) | 830 | 110,000 | 32.24 | 3.753 M3/H | 22 | 3.988 | 2 | 9.5 | ||
| *Natural (I2E+) | 1,000 | 20 | 110,000 | 32.24 | 3.115 M3/H | 31 | 3.048 | 2 | — | |
T75 | 830 | 25 | 110,000 | 32.24 | 3.753 M3/H | 31 | 3.048 | 2 | — | ||
| |||||||||||
| *Butane (I3+) | 3,175 | 110,000 | 32.24 | 2.324 kg/H | 48 | 1.930 | 2 | — | ||
| *Propane (I3 +) | 2,500 | 37 | 110,000 | 32.24 | 2.324 kg/H | 48 | 1.930 | 2 | — | |
| Butane (I3 B /P ) | 3,175 | 110,000 | 32.24 | 2.324 kg/H | 44 | 2.184 | 2 | 18.1 | ||
| Propane (I3 P ) | 2,500 | 110,000 | 32.24 | 2.324 kg/H | 44 | 2.184 | 2 | 24.9 |
Shaded areas are stated in metric equivalents
*Gas valve’s internal regulator disabled.
**Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
22 | JLA Limited | 113429 - 9 |