Connection and Setup of the AD2089

Keyboard Setup

The AD2089 keyboard communicates via RS-232 protocol. Keyboard setup up the keyboard involves setting the keyboard's baud rate, LED brightness, speaker volume, and PTZ motion control.

Setting Keyboard Parameters

The operator can set the following four keyboard parameters:

Baud Rate – 1200 (default), 2400, 4800, 9600, 19,200, and 38,400 bps

LED Brightness - eight brightness levels

Speaker Volume - eight volume levels

Pan/Tilt/Zoom Motor Control – two control options can be set automatically or manually

To Enter Setup Mode

1Turn the three-position keyswitch to the MENU position.

2Press the F1 key. "SETUP BAUD =" appears in the CAMERA display. The current value of the baud rate appears in the ENTER display.

To Change the Baud Rate

1Press the NEXT key to cycle through the available baud rate settings in the forward direction: 1200, 2400, 4800, 9600, 19,200, and 38,400. Press the LAST key to cycle through in the reverse direction. The factory default setting is 1200 baud.

2When the appropriate baud rate appears in the display, press the PROG key to save the selection. You now have the option to either set the brightness level using the following procedure, or exit setup mode by pressing the F1 key, turning the keyswitch to OPERATE, MENU, and then back to OPERATE again.

To Set the Brightness Level

1After baud rate selection has been completed, the message "LEDS =" appears in the CAMERA display. The brightness level (an integer from 1 to 8) appears in the ENTER display. The integer 1 signifies minimum brightness. The integer 8 signifies maximum brightness. 8 is the factory default setting.

2To change the currently displayed brightness level, cycle through the levels using the NEXT or LAST keys to move in forward or reverse direction respectively. Each time the level changes, the intensity of the displayed characters changes as well.

3When the appropriate integer appears in the ENTER display, press the PROG key to save the selection. You now have the option to either set the speaker volume level using the following procedure, or exit setup mode by pressing the F1 key, turning the keyswitch to OPERATE, MENU, and then back to OPERATE again.

To Set the Speaker Volume

1After LED brightness level selection has been completed, the message "SOUND" appears in the CAMERA display. The speaker volume level ("Off" or integer values from 1 to 7) appears in the ENTER display. "Off" indicates the speaker is disabled. The integer 1 signifies the minimum volume level. The integer 7 signifies the maximum volume level. 7 is the factory default setting.

7

Page 15
Image 15
American Dynamics AD2089 manual Keyboard Setup, Setting Keyboard Parameters

AD2089 specifications

The American Dynamics AD2089 is a cutting-edge surveillance camera designed for versatile security applications. Integrating advanced technology and user-friendly features, it stands out as an ideal choice for monitoring both indoor and outdoor environments.

One of the principal features of the AD2089 is its high-resolution imaging capability. It supports up to 1080p full HD video, ensuring that the captured footage is clear and detailed, which is crucial for effective surveillance. The camera is equipped with a 2.8 to 12mm varifocal lens, offering adjustable focal lengths that allow users to customize the field of view according to their specific monitoring needs. This flexibility is particularly beneficial in dynamic environments where the focus may shift frequently.

Another significant characteristic of the AD2089 is its robust low-light performance, thanks to its advanced infrared (IR) capabilities. The camera can function effectively in total darkness, providing night vision support that captures clear images even in minimal lighting conditions. This feature enhances overall security, especially during nighttime when criminal activity is more likely to occur.

The AD2089 also incorporates intelligent video analytics (IVA), enabling real-time analysis of the surveillance footage. This includes features such as motion detection, intrusion detection, and line crossing alarms. By leveraging these analytical capabilities, users can receive timely alerts and have the ability to react quickly to potential security breaches or suspicious activities.

In terms of installation and integration, the AD2089 supports Power over Ethernet (PoE) technology. This simplifies wiring requirements by allowing power and data to be transmitted through a single Ethernet cable, thereby reducing installation costs and efforts. Additionally, the camera is designed to be weather-resistant, making it suitable for outdoor deployment in various environmental conditions.

Furthermore, the AD2089 is equipped with secure data storage options, supporting both local and cloud-based recordings. This ensures that footage is safely archived and easily retrievable, which is essential for any security operation. With features like remote access through mobile devices and a user-friendly interface, the American Dynamics AD2089 stands out as a reliable and powerful surveillance solution, catering to the diverse needs of modern security systems.