5.2.3 UPS Control menu

The UPS Control menu allows the user to access sub-menus that show UPS switch on/off and bypass in/out operation choices. To avoid accidentally powering or unpowering the load when a UPS on/off control choice is mistakenly entered, the UPS will ask the user to confirm the choice.

5.2.4 UPS Status menu

The UPS Status menu allows the user to access sub-menus that show UPS, Battery Pack, utility, and load parameter values. These parameters are described below.

This screen shows the true rms input line voltage. The accuracy of this measurement is ±5% of the full scale value of 285 Vac.

This screen shows the UPS’s true rms line-line output voltage.

The accuracy of this measurement is ±5% of the full scale value of 285 Vac.

This screen shows the applied load as a percentage of the UPS’s full rated capacity.

The accuracy of this measurement is ±4% of the full scale value of 105%.

This screen shows the estimated run time available in minutes. The indication is based on available battery capacity and the applied load. The UPS keeps track of changing battery performance and adjusts the available run time indicated for weak batteries nearing the end of their service life.

This screen shows the internal temperature of the Electronics Unit in degrees Centigrade. The indicated temperature rises when the UPS is operating on-battery and when the ambient temperature rises.

This screen shows the available battery capacity as a percent of the fully charged condition.

This screen shows the frequency to which the UPS’s output is synchronized.

The accuracy of this measurement is ±1% of the full scale value of 63 Hz.

This screen shows the number of Battery Packs connected in the system.

This screen shows the number of XR Battery Packs connected in the system.

This screen shows the number of bad or worn battery Packs connected in the system. To identify the bad Battery Packs, locate the packs having an illuminated Replace Battery indicator.

Page 18
Image 18
American Power Conversion MatrixTM UPS user manual UPS Control menu, UPS Status menu

MatrixTM UPS specifications

American Power Conversion (APC), a leader in power management solutions, has developed the MatrixTM Uninterruptible Power Supply (UPS) system to meet the critical power needs of data center infrastructure. The MatrixTM UPS is designed for scalability, reliability, and efficiency, making it an ideal choice for organizations requiring robust backup power systems.

One of the main features of the MatrixTM UPS is its modular design, which allows for easy configuration and scalability. Organizations can start with a basic setup and expand capacity as needed, ensuring optimal utilization of resources. The system is available in various configurations, enabling customization according to specific power and environmental requirements. This modularity also facilitates easy maintenance and upgrades without significant downtime.

The MatrixTM UPS utilizes advanced technologies, such as dual conversion and intelligent battery management. The dual conversion technology ensures that power is provided in a clean and consistent manner, free from fluctuations and disturbances. Additionally, the system features an integrated battery management system that optimizes battery performance, extends lifespan, and enhances overall efficiency.

One of the standout characteristics of the MatrixTM UPS is its energy efficiency. With a high-efficiency rating, this UPS minimizes energy consumption during operation, which significantly reduces operational costs and contributes to a lower carbon footprint. This is particularly beneficial for businesses looking to adhere to sustainability goals while maintaining reliable power supply.

Another key feature is the intuitive user interface that simplifies monitoring and control. Users can easily access real-time information on power status, battery health, and operational efficiency through a graphical LCD. Remote management capabilities enable administrators to monitor the system from any location, providing added flexibility and ensuring quick response times in case of power issues.

The MatrixTM UPS also prioritizes redundancy, with features such as N+1 architecture, ensuring that backup power is reliable even in the event of component failure. This level of redundancy is crucial for mission-critical applications where power interruptions can lead to significant operational disruptions.

In summary, the American Power Conversion MatrixTM UPS stands out with its modular design, advanced technology, high energy efficiency, and user-friendly interface. These characteristics make it a reliable solution for businesses looking to ensure continuity of operations in an increasingly power-dependent environment. With its robust capabilities, the MatrixTM UPS positions itself as a cornerstone for effective power management in data centers and beyond.