INSTALL TOILET

6

BOLT CAP

WASHER

NUT

BOLTS

CLOSET BOLT

INSTALL TOILET

a.Position toilet squarely to wall and, with a rocking motion, press bowl down fully on wax ring and flange. Alternately

tighten nuts until toilet is firmly seated on floor.

! CAUTION:

DO NOT OVERTIGHTEN NUTS

OR BASE MAY BE DAMAGED!

b.Install caps on washers. (If necessary, cut bolt height to size before installing caps.)

c.Smooth off the bead of sealant around base. Remove excess sealant.

CLOSET FLANGE

7INSTALL TOILET SEAT Install toilet seat in accordance with manufacturer's directions.

8a

Before continuing, determine the type of water supply connection you have from

 

the chart below and use the appropriate assembly parts required to properly

 

reconnect the water supply. DO NOT use plumber's putty to seal these fittings.

METAL/COPPER

METAL FLANGED

METAL SPIRAL

VINYL/BRAIDED

FLARED TUBING

TUBING

TUBING

CONNECTOR

LOCK NUT

LOCK NUT

LOCK NUT

LOCK NUT

CONE

EXISTING

EXISTING

COUPLING

WASHER

WASHER

CONE

NUT

 

COUPLING

EXISTING

WASHER

 

 

 

COUPLING

COUPLING

 

NUT

 

 

NUT

NUT

 

WATER

WATER

WATER

WATER

SHUT-OFF

SHUT-OFF

SHUT-OFF

SHUT-OFF

These parts must be used as

Use existing

Use existing spiral cone

Captive cone

illustrated to insure water-tight

coupling nut

washer. Fluidmaster cone

washers already

connection. Use of existing

and washer.

washer may not seal

included. No

coupling nut may result in

 

completely on spiral type

additional

water leakage. Water supply

 

supply line.

washers needed.

tube or pipe must extend at

 

 

 

least 1/2" inside threaded

 

 

 

shank of valve (does not

 

 

 

apply to flanged tubing).

 

 

 

CAUTION: DO NOT USE

 

CAUTION: Overtightening of

CONE WASHER WITH

 

LOCK NUT or COUPLING

 

NUT could result in breakage

PLASTIC SUPPLY LINE.

 

 

and potential flooding.

 

 

 

8b

With correct washers in place (see Step 8a), tighten COUPLING NUT 1/4 turn beyond hand tight.

DO NOT OVERTIGHTEN.

9

TOP

ARM NIPPLE

 

 

 

 

REFILL

 

 

TUBE

TANK

 

 

LEVER

CRITICAL LEVEL

 

 

MARK ("C.L.")

 

 

MUST BE

 

 

1" ABOVE

 

 

OVERFLOW PIPE

FLOAT

 

 

 

 

CUP

Fig. 9a

 

 

FILL

 

 

VALVE

 

 

VALVE

WATER LEVEL

 

ADJUSTMENT

 

BODY

 

ROD

 

 

 

ADJUSTABLE

 

 

HEIGHT

 

 

 

SHANK

 

 

WASHER

 

LOCK NUT

THREADED

 

CONE WASHER

SHANK

 

PARTS FOR WATER

 

 

 

COUPLING NUT

CONNECTION

 

(SEE STEP 8)

Diagram 1

(HAND TIGHT ONLY)

 

ADJUSTMENTS:

Turn supply on.

a.Adjust water level to level indicated on tank by adjusting float cup. See Step 10.

b.If bowl fails to siphon, an adjustment may be required with the lift chain. Simply remove the bead chain from the retainment clip (see Fig. 9a) and take up slack on the chain, and reinsert on lift rod. Make sure the chain is not too taut.

10

Turn on water supply. Submerge the FLOAT CUP under the water for 30 seconds. Adjust the water to desired level by turning WATER LEVEL ADJUSTMENT ROD and moving FLOAT CUP up or down.