American Standard 2064.90X installation instructions Install Handles, Figure A, Service

Models: 2064.90X

1 4
Download 4 pages 49.63 Kb
Page 2
Image 2
9

3 VALVE ASSEMBLY

Install LOCKNUTS (1) and RUBBER WASHERS (2) onto valve shanks.

Push TUBING (3) ends into VALVE (4) side outlets. Insert VALVES (4) into mounting holes from underside of ledge.

Press TEE (5) onto SPOUT SHANK (6) making certain that the O-RING (7) is properly seated on SHANK (6). Push COUPLING (8) into TEE (5) and attach to SPOUT SHANK (6) and tighten using a 10mm (3/8'') hex wrench. Tighten COUPLING (8) using a 10mm (3/8") Hex wrench. (FOR 2064.901). Use COUPLING (8a) for fitting less spray.

Thread of VALVE BODY (4) should extend at least 5/16 inch above MOUNTING SURFACE (11). If necessary, adjust LOCKNUT (1).

9

10

11MOUNTING

SURFACE

9

Place RUBBER RING (10) into ESCUTCHEON ADAPTERS (9) and thread onto

 

valves until snug against internal stop.

10

Tighten LOCKNUT (1) with WRENCH supplied to secure VALVE (4) position.

Slide FERRULE (12) and COUPLING NUT (13) to outlet of VALVE (4) and tighten COUPLING NUT (13) firmly.

Connect HOT water supply to inlet of left VALVE and COLD water supply to inlet of right VALVE using appropriate connector.

9

10

HOT

4

 

 

7

12

13

6

 

 

 

5/16'' MIN.

4

11

4 INSTALL HANDLES 2

Wrench

1

MOUNTING

3

12

4

 

 

 

 

 

SURFACE

 

5

 

 

 

 

8a

 

8

 

 

 

13

COLD

4 INSTALL HANDLES

 

 

 

Push ADAPTER (1) on VALVE STEM (2). See figure "A". Tighten

 

 

 

STEM SCREW (3) to secure ADAPTER (1).

 

 

THREAD ON

 

 

 

TO DECK

Find correct position of LEVER HANDLE ASSEMBLY (4) by adjusting

 

4

ADAPTER

 

 

male teeth on ADAPTER (1) to female teeth in HANDLE (4).

SPLINE

 

 

 

 

TOP

Thread LEVER HANDLE ASSEMBLY (4) onto DECK ADAPTER (5)

END UP

 

 

 

 

 

 

until snug against mounting surface.

 

 

1

 

Figure "A"

 

3

 

 

2

 

 

 

5

5 SERVICE

To change direction of handle rotation, proceed as follows:

Figure "A" Turn valve to OFF position.

5 SERVICE Thread counter-clock wise HANDLE BASE (1) to remove HANDLE ASSEMBLY (2) from ESCUTCHEON BASE (3).

Manual background Use a flat blade screw driver to remove SPRING CLIP (4).1 Manual backgroundManual background 2

Manual background Lift STOP WASHER (5), turn 90˚ and replace.

Manual background Replace SPRING CLIP (4). Manual background Reinstall HANDLE ASSEMBLY (2).

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.

VALVE

5

90˚

 

4

3

M968830 Rev . 1 . 4

Page 2
Image 2
American Standard 2064.90X installation instructions Install Handles, Figure A, Service