WHIRLPOOL ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
!WARNING: When using electrical products, basic precautions should always be observed, including the following:
1.DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a
2.Grounding is required. The unit should be installed by a licensed electrician and grounded.
3.Permit access for servicing motor as noted.
4.All building materials and wiring should be routed away from the pump body and heater (if equipped).
PLEASE SEE THE FOLLOWING TABLE FOR GFCI CIRCUIT REQUIREMENTS:
GFCI CIRCUIT REQUIREMENTS: | FOR MODEL NUMBERS: | |
|
| |
The whirlpool should be installed on a 120 vac, 15 amp dedicated |
| |
GFCI circuit. | 2422, 2425, 2645, 2732 | |
The circuit should be | ||
2771, 2908 | ||
circuit must be a three (3) wire circuit from the electrical supply panel. A | ||
ALL MODELS | ||
grounded neutral wire and a third wire, earth ground, are essential. | ||
| ||
Optional heater requires a separate 15 amp maximum GFCI circuit. |
| |
|
| |
The whirlpool should be installed on a 120 vac, 20 amp dedicated |
| |
GFCI circuit. | 6060, 2775, 2773, 2711, | |
| ||
The circuit should be | 2774, 7236 | |
circuit must be a three (3) wire circuit from the electrical supply panel. A | ALL MODELS | |
grounded neutral wire and a third wire, earth ground, are essential. | ||
| ||
Optional heater requires a separate 15 amp maximum GFCI circuit. |
| |
|
|
120 VAC
WHITE |
| BLACK |
|
|
| ||
|
|
|
|
GND.
PUMP/MOTOR
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
WIRE SELECTION GUIDE
|
| Maximum distance from | ||||
|
|
| fusebox to motor |
| ||
|
|
|
|
|
|
|
Wire Length | 50' |
| 100' | 150' |
| 200' |
|
|
|
|
|
|
|
|
|
| 115V Power Line |
| ||
|
|
|
|
|
|
|
Wire Size (AWG) | 12 |
| 10 | 8 |
| 8 |
|
|
|
|
|
|
|
The sizes shown on this
chart are recommendations
for copper conductors only. Always follow local and national electrical codes
12 |