ELECTRICAL INSTALLATION INSTRUCTIONS

All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.

WARNING:

When using electrical products, basic precautions should always be observed, including the following:

1.DANGER: RISK OF ELECTRIC SHOCK

Connect only to a circuit protected by a ground-fault circuit interrupter.

2.Grounding is required. The unit should be installed by a licensed electrician and grounded.

3.Install to permit access for servicing.

4.All building materials and wiring should be routed away from the pump body and heater (if equipped).

2.1 HORSEPOWER MODELS:

The whirlpool should be installed on a 120 vac, 20 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit fron the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT.

ELECTRICAL INSTALLATION

 

SEPARATE 20 AMP GFCI

 

120 VAC

 

WHIRLPOOL MOUNTED

 

AIR or ELECTRONIC SWITCH

 

or

 

WALL TIMER-

WHITE

(2.1HP AIRSWITCH MODELS ONLY)

BLACK

 

PUMP/MOTOR

 

GND.

ELECTRICAL DIAGRAM

READ AND FOLLOW ALL INSTRUCTIONS

751753-100 Rev. J

(3)

Page 3
Image 3
American Standard 2709.XXXW installation instructions Electrical Diagram Read and Follow ALL Instructions