EVOLUTION™ 5' X 36"
WHIRLPOOL AND BATHING POOL
60"
(1524mm)
HIGH GLOSS
11"
(279mm)
CUT OUT IN FLOOR |
|
|
|
|
|
|
| ||||||
FOR DRAIN | 3" |
|
|
|
|
|
|
|
| ||||
| (76mm) |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 6" |
|
|
|
|
|
| 36" | |||||
| (152mm) |
|
|
|
| (914mm) | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| (191mm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| |||
| (349mm) |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
36"
(914mm)
C/L OF
OVERFLOW
(546mm)
20"(C)(511mm) (508mm)
DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE
OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124.1 AND A112.19.7.
GENERAL SPECIFICATIONS FOR 2771V WHIRLPOOL
INSTALLED SIZE |
|
|
|
|
|
|
|
|
|
|
| 60 x 36 x | ||||
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| (1524mm x 914 mm x 546mm) | |||||
WEIGHT |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 75 Lbs. (34 Kg.) | |
|
|
|
|
|
|
|
|
|
|
|
| |||||
WEIGHT w/WATER |
|
|
|
|
|
|
|
|
|
| 800 Lbs. (363 Kg.) | |||||
|
|
|
|
|
|
|
|
|
| |||||||
GAL. TO OVERFLOW |
|
|
|
|
|
|
|
|
|
|
| 87 Gal. (329 L.) | ||||
|
|
|
|
|
|
|
|
|
| |||||||
MIN. OPERATING GAL. |
|
|
|
|
|
|
|
| 50 Gal. (189 L.) | |||||||
|
|
|
|
|
|
|
| |||||||||
BATHING WELL AT SUMP |
|
|
|
|
|
| ||||||||||
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
| (1048mm x 667mm) | ||||
BATHING WELL AT RIM |
|
| ||||||||||||||
|
| |||||||||||||||
WATER DEPTH TO OVERFLOW |
|
|
|
| ||||||||||||
|
|
|
| |||||||||||||
FLOOR LOADING |
|
|
|
|
| 53 Lbs./Sq. Ft. (260 Kgs/Sq. m.) | ||||||||||
(PROJECTED AREA) |
|
|
|
|
|
|
|
|
| WHIRLPOOL ELECTRICAL SPECIFICATIONS |
PUMP | 1.4 HP, 9.7 AMPS, 120V. |
NOTES:
GENERAL SPECIFICATIONS FOR 2771V BATHING POOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM |
|
|
| |||
WATER DEPTH TO OVERFLOW |
|
|
| |||
FLOOR LOADING |
|
| 52 Lbs./Sq.Ft. (255 Kgs./Sq.m) | |||
|
| |||||
(PROJECTED AREA) |
|
|
|
BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA TYPE INSTALLATION. SUPPORT OF BATH BY SUMP BEDDING. SUPPORT AND ENCLOSING MATERIAL BY OTHERS.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.
■OPTIONAL 3 WALL TILING BEAD. KIT No.
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1 These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided leaflet.
| H94 |
| |
© 2008 AS America Inc. | Revised 3/06 | ||
|