Cisco Systems 2960 Cable and Adapter Specifications, SFP Module Cable Specifications

Models: 2960

1 108
Download 108 pages 14.27 Kb
Page 86
Image 86
Cable and Adapter Specifications

Appendix A Connector and Cable Specifications

Cable and Adapter Specifications

Figure A-4 10/100/1000 Port Pinouts

Pin Label

1TP0+

2TP0-

3TP1+

4TP2+

5TP2-

6TP1-

7TP3+

8TP3-

Console Port

1 2 3 4 5 6 7 8

60915

The console port uses an 8-pin RJ-45 connector, which is described in Table A-2and Table A-3. The supplied RJ-45-to-DB-9 adapter cable is used to connect the console port of the switch to a console PC. You need to provide a RJ-45-to-DB-25 female DTE adapter if you want to connect the switch console port to a terminal. You can order a kit (part number ACS-DSBUASYN=) containing that adapter from Cisco. For console port and adapter pinout information, see Table A-2and Table A-3.

Cable and Adapter Specifications

These sections describe the cables and adapters used with Catalyst 2960 switches:

SFP Module Cable Specifications, page A-4

Two Twisted-Pair Cable Pinouts, page A-6

Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports, page A-6

Crossover Cable and Adapter Pinouts, page A-7

SFP Module Cable Specifications

Table A-1lists the cable specifications for the fiber-optic SFP module connections. Each port must match the wave-length specifications on the other end of the cable, and for reliable communications, the cable must not exceed the required cable length. Copper 1000BASE-T SFP transceivers use standard four twisted-pair, Category 5 or greater cable at lengths up to 328 feet (100 meters).

Catalyst 2960 Switch Hardware Installation Guide

 

A-4

OL-7075-05

 

 

 

Page 86
Image 86
Cisco Systems 2960 specifications Cable and Adapter Specifications, SFP Module Cable Specifications, Console Port