14 EverClean™ Finish Care Instructions

11 INSTALL HANDLES (Lever)

Turn HANDLE STEM (1) to "OFF" position.

Place the HANDLE ADAPTER (2) on the HANDLE STEM (1).

Install the ADAPTER SCREW (3) and tighten securely. Position LEVER HANDLE (4) and place on ADAPTER (2).

Install the HANDLE SCREW (5) and tighten securely with hex wrench supplied.

515 To change direction of handle rotation, proceed as follows:

4

3

2

1

INSTALL HANDLES (Acrylic)

 

Turn HANDLE STEM (1) to "OFF"

 

 

 

 

position.

4

 

Place the ACRYLIC HANDLE (2)

 

 

 

 

 

on the HANDLE STEM (1).

3

 

Install the HANDLE SCREW (3)

 

 

 

 

 

and tighten securely.

 

 

Push in INDEX BUTTON (4).

2

 

 

 

 

1

12 TEST INSTALLED FITTING

5

With HANDLES (1) in OFF position, turn on WATER

1

SUPPLIES (2) and check all connections for leaks.

3

 

Operate both HANDLES (1) to flush water

 

lines thoroughly.

 

Rotate TRANSFER VALVE (5) from rim wash to

 

spray several times to check operation.

1

 

13 CHECK DRAIN CONNECTIONS

Pull up POP-UP KNOB (3) and fill Bidet with water. Check that DRAIN STOPPER (4) makes a good seal and retains water in Bidet. If STOPPER (4) does not seal properly, please refer to “Troubleshooting Guide” in these instructions.

Push POP-UP KNOB (3) down and check all drain connections and "P" trap for leaks. Tighten

if necessary.

4

SPRAY

2

2

14 EverClean™ Finish Care Instructions

American Standard’s EverClean finish will wipe clean with a soft, dry cloth.

A soft cloth with clean water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.

SERVICE

15 To change direction of handle rotation, proceed as follows:

Turn VALVE to OFF position.

Loosen HANDLE SCREW (1) .

Pull HANDLE (2) off ADAPTER (3). Loosen ADAPTER SCREW (4) and pull off ADAPTER (3).

Turn ADAPTER (3) 90˚ in a way that flat in ADAPTER (3) catches on the other FLAT on VALVE STEM (5).

Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2). Tighten HANDLE SCREW (1).

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.