REMOTE BLOWER LOCATION OPTION

IMPORTANT! It is not necessary that the blower motor be relocated. This option is provided for the case that a particular installation makes this effort practical.

NOTE: Relocating blower motor from factory installed location, see photo W, will require disassembly of air blower from mounting board. Keep all hardware for reattachment at new location. Additional hardware will be required depending upon final desired position of air blower. Follow all instructions listed below.

W.

TYPICAL VIEW

NOTE: Installing the blower in a remote location will reduce the system efficiency.

NOTE: Relocating a blower motor still requires a service access for the blower.

NOTE: All materials needed for the relocation must be supplied by the installer. This includes ordering a longer control panel cable (P/N 75405-0071A).

A separate circuit, which must be protected by the Ground Fault Circuit Interrupter (GFCI), is required in the remote location. Electrical connections should be performed by a licensed electrician.

Choose a space as close to the bath as possible so the system works as efficiently as possible. The space must be at least 30 cubic feet and the blower must be mounted at least  inches above the floor and  inches minimum away from any wall. The blower must NOT be installed in an attic area.

The blower motor must be located within 1 feet of rigid piping from the bath air manifold. This limitation is for the total pipe length and applies to any direction changes and elbows. There can be no more than six changes of direction. There should be as few direction changes as possible and the piping installation must meet all requirements of local plumbing and building codes.

Disconnect the blower from the flexible hose as shown in photo X. Do NOT remove the check valve manifold that is mounted to the underside of the air bath. The manifold MUST remain mounted above the tub overflow level as shown in X.

X.

TYPICAL VIEW

Do NOT move check valve manifold

Use 1 1/” PVC rigid piping and couplings to extend the blower motor location as shown in photos Y and Z. Detach the flexible hose section from the blower end and extend the air line by adding the appropriate length of PVC piping. Mount the blower in a horizontal direction using the mounting screws provided with the air bath system. Do NOT glue piping to either the manifold or blower. These couplings MUST be attached to the piping with screws as shown in photos Y and Z. Glue only the PVC piping and couplings needed to extend the air line. Let the glued couplings set overnight before attaching the blower and manifold couplings with screws.

CAUTION: It is imperative to let the glued piping set overnight as there may be fumes from the glue that could be ignited if not allowed to dissipate.

Y.

Z.

15

754063-100 Rev. B

Page 15
Image 15
American Standard 3574, 3575, 3572 manual Remote Blower Location Option, Typical View

3572, 3575, 3574 specifications

American Standard has long been a trusted name in the plumbing and bathroom fixture industry, and their models 3575, 3574, and 3572 showcase the brand's commitment to quality, innovation, and design excellence. Each of these models presents a unique combination of features and characteristics that cater to diverse consumer needs and preferences.

The American Standard 3575 is a notable bathroom faucet designed with both functionality and aesthetics in mind. It features a sleek, modern design that effortlessly enhances the visual appeal of any bathroom decor. One of its standout attributes is the WaterSense certification, which ensures water conservation without sacrificing performance. The faucet incorporates a ceramic disc valve for smooth operation and longevity, significantly reducing the risk of leaks and drips.

Next, the American Standard 3574 offers a blend of traditional and contemporary styles, making it an excellent choice for various bathroom settings. This model also boasts WaterSense certification, promoting eco-friendly usage while preserving water efficiency. Its intuitive single-handle design allows for easy adjustment of water temperature and flow, ensuring convenience during use. Additional features include a high-arc spout that provides ample clearance for filling pots and vases, enhancing functionality.

Finally, the American Standard 3572 presents an innovative solution for those seeking a user-friendly, accessible faucet option. This model features a unique touchless activation, allowing users to turn the water on and off with a simple wave of the hand. This technology not only enhances hygiene by minimizing contact but also bolsters water efficiency. The 3572 is designed with an easy-to-install system, making it suitable for both DIY enthusiasts and professionals.

In conclusion, the American Standard 3575, 3574, and 3572 models reflect the brand's dedication to blending technology with style. From water-saving features and durable construction to user-friendly interfaces, these faucets are designed to meet the demands of modern bathrooms while enhancing overall user experience. Whether one is looking for cutting-edge convenience or timeless elegance, American Standard's offerings provide reliable and stylish solutions for every space.